User`s manual

Printer Adjustments
43
Adjusting the Transparent sensor
The transparent sensor is selected.1.
Install only the liner media (label backing paper) with the 2.
label media removed so that it will pass between the platen
roller and the media sensor. (Be careful that media with
black marks does not pass the media sensor.) Then close the
damper arm and the printhead.
Label
Media gap
Bottom sensor
Upper sensor
Liner media
If the Pause Key is pressed then released while the MENU key 3.
is continually pressed, the sensor is automatically adjusted.
Sensor Cal Mode
Executing
MENU
PAUSE
Press/ReleaseHold
When automatic adjustment stops normally, "Succeeded" is 4.
displayed by the LCD. If it stops abnormally (adjustment is
impossible), ERROR LED ashes and "Failed" is displayed on
the LCD.
Sensor Cal Mode
Succeeded
If the STOP key is pressed, the Printer completes sensor 5.
adjustment and the printer restarts.
Installing the Media (p.24)
Quick Sensor Selection Method
(Transparent
Reective)
(p.42)
Sensor Adjustments and Calibration