User`s manual
Printer Adjustments
42
3
Sensor Adjustments and Calibration
The sensing level of both the transparent (see thru) and reective sensors
is adjusted separately and independently. Firstly, the sensor type must
be selected using the Sensor Method Selection shown below. Then the
adjustment and calibration of the sensor can be made.
Entering Sensor Adjustment Mode
Turn on the power while pushing the PAUSE key, FEED key, 1.
and STOP key simultaneously.
Power Switch
STOP
FEED
PAUSE
After "Sensor Cal Mode" lights up, release the keys to change 2.
the printer to sensor adjustment setting mode.
POWER ERROR
Sensor Cal Mode
See Through
Quick Sensor Selection Method
(Transparent
Reective)
To switch from transparent to reective sensor, hold down the MENU key
and then press the STOP key. Each time you press the STOP key, you switch
to back and forth between the two sensor types.
If the transparent sensor is selected, "See Through" is displayed and the
buzzer sounds once. If the reective sensor is selected, "Reect" is displayed
and the buzzer sounds twice.
POWER ERROR
Sensor Cal Mode
Reect
STOP
MENU
Press/ReleaseHold
Installing the Media (p.24)