User`s manual

Printer Operation
38
2
Zebra® Emulation
Mode Settings
[Zebra® Emulation]
Top Menu Sub Menu Default Menu Remarks
Page Setup Print Speed 7 IPS 2 to 7 IPS Printing speed setting.
Print Darkness 12 00 to 30 Adjusting print darkness.
Darkness Adjust
[Darkness Adj]
00 -10 to 10 Fine adjustment of darkness commands.
Continuous Media
Length
[Cont Media Len]
4.00 inch
101.6 mm
0.25 to 32.00 inch
6.4 to 812.8 mm
Setting media length of continuous media.
Lower level = during mm mode.
Vertical Position
[Vertical Pos]
0.00 inch
0.0 mm
-1.00 to 1.00 inch
-25.4 to 25.4 mm
Adjusting printing start position.
Horizontal Shift
[Horizontal Shif]
0.00 inch
0.0 mm
-1.00 to 1.00 inch
-25.4 to 25.4 mm
Adjusting horizontal image position.
Media Sensor See Through See Through
Reect
None
Selecting media sensor.
Small Media
Adjustment
[Small Media Adj]
O On
O
Setting for small media.
Small Media Length
[Small Media Len]
1.00 inch
25.4 mm
0.25 to 1.00 inch
6.4 to 25.4 mm
Setting media length for small media.
Symbol Set PM 50 symbols Setting symbol set.
System Setup Sensor Monitor Displays level of sensor that is currently
selected.
Sensor Level 1.4 V 0.0 V to 3.0 V Selects threshold of the sensor.
Paper End Level 2.80 V 0.01 V to 3.00 V Sets the paper end level.
Error Reporting
[Error Report]
On Printing On Printing
Immediate
Setting for error report.
Cover Open Sensor
[Cover Sensor]
O On
O
Sets the cover open sensor.
Buzzer Select Exec/Err Exec/Err
All
Error
Key
None
Setting buzzer sounding conditions.
Metric/Inch
[Metric/Inch Sel]
Inch Inch
mm
Sets the units.
Max Media Length
[Max Media Len]
10.00 inch
254.0 mm
1.00 to 50.00 inch
25.4 to 1270.0 mm
Sets the maximum media length.
Settings Lock O On
O
Prevents a command changing the set value.
Keyboard Lock O On
O
Prevents a change by a key operation.
Note: Hold down the Menu Key for at least 4
seconds to enter the Menu Setup Mode when
setting the "On" menu.
Media Power Up O On
O
Selects whether or not to initiate media
measurement when the power in ON.
CI Lock O On
O
Activates/deactivates the CI command.
Emulation Select
[Emulation Sel]
ZPI2 DM4
DMI
DPP
ZPI2
Selects DataMax®/Zebra® compatibility
DM4: DataMax® 400
DMI: DataMax® IClass
DPP: DataMax® Prodigy Plus®
ZPI2: Zebra® 2844Z
Emulation Auto
Detect
[Emulation Auto]
On On
O
Full Auto
Setting emulation (as above) auto detection.