User`s manual

Printer Operation
37
Top Menu Sub Menu Default Menu Remarks
Service Counter ****.*** km Displays the service counter.
Cut Counter Displays the cut count.
Sensor Monitor *.* V Displays the sensor level.
Option Interface
[Option I/F]
None
LAN
Displays the presence/absence of the optional
interface.
Test Mode Print Pattern
Current Cong
Current Cong
Global Cong
Sample
Executes the test pattern.
Head Check No Yes
No
Executes head check.
Factory Default No Yes
No
Initializes the set values of the conguration
set to the state when the unit was shipped
from the factory.
Hex Dump No Yes
No
Sets the hex dump mode.
Serial Monitor Displays the state of the serial interface.
Auto Calibration
[Auto Cal]
See Through See Through
Reect
Executes the calibration of the sensor.
Sensor Monitor See Through See Through
Reect
Displays the level of the sensor.
Global
conguration
[Global Cong]
Cong Set 1 Cong Set 1
Cong Set 2
Cong Set 3
Sets the Cong Set.
Note: To restore factory default settings, turn on printer power while pushing the MENU and PAUSE keys
simultaneously, then press the FEED key and the STOP key sequentially.
Mode Settings