User`s manual

20
2. PROGRAM LOADER (PLM 2000)
Using the software Program Loader Module PLM 2000, ECR's data can be uploaded / edited on PC
and restored to ECR.
3. ESF DATA TRANSFER (Electronic Store & Forward)
All registrations or only the selected transaction data by PGM-181 which have been performed only in
the R position are recorded in the ESF memory (1st optional RAM board). System function flag
"ESF function available" [SF-4.h=1] must be selected.
When the 1st optional RAM board for ESF is first installed, X-79 report must be taken to clear
in the Z1/P key lock position on ECR.
ESF DATA TRANSFER
The journal data in the ESF memory can be transmitted to PC by remote memory dump (#79) using
PC batch communication.
PC ESF remote memory dump (ESF data transmitted to PC)
Using batch communication (RS232C)
PC can take all the stored journal data and the ESF status in ECR by using a command (X79/Z79).
When Z79 is taken by PC, all the stored journal data and the ESF status data will be cleared. X79 does
not clear the data.
Using PC-IRC function (RS485)
PC as the IRC master can take all the stored journal data and the ESF status in one ECR using a
command (X79/Z79). The consolidation function is not available. When Z79 is taken by PC, all the
stored journal data and the ESF status data will be cleared.
ECR ESF status check report (ESF data not transmitted to the PC)
Only the ESF status (number of used records, remaining records and total number of records) is printed.
The stored journal data will not be printed. When the report is issued in the Z1/P position, all the stored
journal data and the ESF status data will be cleared.