User`s manual

15
3. SCALE
A scale which has RS232C interface can be used through channel B or optional channel D of LX IF7-
1 K-UNIT.
Recommended models:
DIGI DS-640
BARKEL CX-9, CX-10
Select the scale which matches the scale information described in the following pages.
Refer to VIII. Cable Connection (page 27).
ECR SETTINGS
a) The following system function flags must be programmed;
1/0 bit 1 0
a Scale interface : W protocol ICL protocol
b
c
Scale type selection [b,c]:
[00] standard; [01] EC; [10] USA; [11] France
SF-5
e
Weight unit is "kg" ("Kg" for France)
up to 9.999 of the manual quantity entry is permitted for standard and EC
up to 99.999 is permitted for USA and France
Weight unit is "lb"
(99.99)
SF-90
SF-92
SF-93
c
With scale
[SF-90] ch-B, [SF-92] ch-D, [SF-93] ch-E
without scale
a Character structure: Odd parity Even parity
b Character structure: 8-bit data 7-bit data
c Character structure: Parity permitted prohibited
d Character structure: 2 stop bits 1 stop bit
e
f
g
SF-94
ch-B
SF-98
ch-D
SF-100
ch-E
h
Baud Rate [f,g,h]:
[000] 38400 bps; [001] 19200 bps; [010] 9600 bps; [011] 4800 bps;
[100] 2400 bps; [101] 1200 bps; [110] 600 bps; [111] 300 bps (for ch-D,E)
b) Set following PLU function flags;
1/0 bit 1 0
a
Tare weight entry compulsory [PF-2.a=1]
not compulsory
PF-1
b
Manual tare weight entry permitted [PF-2.a=1]
prohibited
1
a
Scaleable item [b=1]
Non-scaleable item
PF-2
1
b
Decimal number entry permitted
prohibited
e) Assign SCALE key (#222) and TARE key
(#236) by PGM-101 if required.
SCALE SETTINGS
Set communication settings (baud rate, data length, stop bit, parity) to match the ECR settings above.