User`s manual
14
Settings for scanner from third party
When you are using BHS-6060 and BCH-5442-STA supplied from third party or a scanner of other
manufacturers, some settings are required. Perform the following steps:
1. Connect the scanner to the correct ECR's interface port. RTS signal need to be wired.
Refer to VIII. Cable Connection (page 28).
2. Set the system function flags of ECR. Refer to the previous page.
3. Set the followings on the scanner by a preset bar code menu or a dip switch of the scanner.
a. Message (not text) RTS/CTS handshake must be set. Some scanner has this fixed.
b. If there is a selection either "scanner ready" or "data ready", choose "data ready".
c. "Baud rate, data length, stop bit, parity" should be matched to the ECR's settings.
d. Set the data transmission format of the scanner. Refer to the previous page.
4. Check the scanner works with ECR.
5. If the scanner does not work, the timing of the scanner which deactivates RTS may be fast.
In order to delay the deactivating timing, increase the trailer (post-amble, terminator) to 2 byte data
from 1 byte data. Set "CR, LF" for example. Then the scanner will work with ECR.