User`s manual
13
2. SCANNER
Handy scanner models HC66R (BHS-6060/R) and BCH5442-STA supplied by ECR can be used
immediately after the scanner cable is connected to channel B.
Refer to VIII. Cable Connection (page 28).
HC66R and BCH5442-STA’s factory settings
9600 bps, 7-bit data, even parity, 1 stop bit
ECR SETTINGS
1/0 bit 1 0
SF-90
SF-92
SF-93
b
With scanner
[SF-90] ch-B, [SF-92] ch-D, [SF-93] ch-E
without scanner
a Character structure: Odd parity
Even parity
b Character structure: 8-bit data
7-bit data
c Character structure: Parity permitted prohibited
d Character structure: 2 stop bits
1 stop bit
e
f
g
SF-94
ch-B
SF-98
ch-D
SF-100
ch-E
h
Baud Rate [f,g,h]:
[000] 38400 bps; [001] 19200 bps; [010] 9600 bps; [011] 4800 bps;
[100] 2400 bps; [101] 1200 bps; [110] 600 bps; [111] 300 bps (only for ch-D,E)
SCANNER SETTINGS
Set following communication settings by a preset bar code menu or a dip switch of scanner to match
ECR's setting;
baud rate, data length, stop bit, parity, RTS/CTS handshake (fixed)
SCANNER INFORMATION
If scanner's data format is as below, it can be used.
data (numeric: 30
H
~ 39
H
)
header (any data except 30
H
~39
H
, normally STX 02
H
is used)
code mark (any data except 30
H
~39
H
, no data is also available)
trailer (must be 1-byte data)
data: 00
H
~ 0F
H
, normally CR (0D
H
) is used