User`s manual

CBM-292/293 Users Manual
68 CITIZEN
ESC ¥ n1 n2
[Function] Specifying the Relative Positions
[Code] <1B>H<5C>H<n1>< n2>
[Range] {0
n1
FF}
{0
n2
FF} Data is described in Hex code.
[Outline] The printing start position is specified in the number of dots(1/203 inch unit) from the
current position.
Rightward direction is taken as plus and leftward direction as minus.
To specify N dot in minus (left) direction, use a complement of N for assignment.
N dots = 65536
N
The number of dots is divided by 256, whose quotient is taken as n2 and the
residual as n1.
[Caution]
Specifying exceeding the top of line or the end of line is ignored.
[Default]
The initial value is not specified.
[See Also] ESC $
[Sample Program]
[Print Results]
See Sample Program and Print Results for ESC $ on Page 67.