User`s manual
CBM-292/293 User’s Manual
52 CITIZEN
ESC 3 n
[Function] Setting Line Feed Rate of Minimum Pitch
[Code] <1B>H<33>H<n>
[Range] {0
≤
n
≤
FF} Data is described in Hex code.
[Outline] The line feed rate per line is specified by n/360 inch.
Since an actual mechanical pitch is 1/203 inch, it is internally converted approximate to the
value specified with this command.
[Default]
•
The initial value is n = 60 (1/6 inch) (18H), being 4.23 mm line feed rate.
[Sample Program]
[Print Results]
See Sample Program and Print Results for ESC 2 on Page 51.