Operating instructions
— 42 —
8. POWER CONNECTOR
This connector is to supply the power from the special AC adapter(27AD).
Connector Schematic
No.
1
2
Function
7.2V
GND
Jack used : HEC0470-01-640 (HOSHIDEN) or its equivalent
Applicable plug : JXP series type A (I.D.: 2.45 mm, O.D.: 5.5 mm) (HOSHIDEN)
or its equivalent
Inner terminal : Minus Pole (GND)
Outer terminal : Plus pole
CAUTION:
• Be sure to use the specified AC adapter. Use of any other power source could cause
trouble to or break the printer.
• Do not connect the power source with different polarity.
• If the printer will not be used for a long period of time, unplug the power plug from
the wall outlet.
12