Setup guide
CITIZEN OPOS DRIVER 1.8 Setup Guide
30
6.4 CT-S4000 Series
DIP Switch Setting
DSW No. Function Setting Description
8
INIT
(when serial interface is used)
OFF Disabled
Memory Switch Setting
MSW
No.
Function Setting Description
1-1 Power ON notify setting OFF Enabled
1-2 Input buffer OFF 4KB
1-3 Busy condition ON Buffer full
1-4 Receiving error character OFF Character ?
1-5 CR mode OFF Disabled
1-7
Select DSR signal
(when serial interface is used)
OFF DSR
1-8
Select INIT signal
(when serial interface is used)
OFF -
2-2 Auto cutter operation ON Enabled
2-4 Full column printing OFF Print immediately
3-1 Auto cutter restore OFF L/F enabled
3-3
Parallel 31Pin
(when USB and parallel IF are
used)
OFF Reset
3-7 CBM1000-compatible mode ON Compatible
3-8 Cover opened while printing OFF Auto restore
4-8 Forced partial OFF Disabled
5-2 Vertical basic calculation pitch OFF 360 dots
5-3
USB mode
(when USB interface is used)
ON Printer class
5-5 Power OFF notify Disabled -
7-6 DMA control Enabled -
9-1 Code page Katakana -
9-2 Foreign language characters Japan -
9-3 Kanji Enabled -
9-4 JIS/Shift-JIS Shift-JIS -
10-3
ACK output timing
(when USB and parallel IF are
used)
Before BUSY -