P381 NO ARC R/C SPC
Details
Corner chamfering II or corner rounding II was commanded in the arc interpolation block
though it is out of specifications.
Remedy
- Check the specifications.
P382 CORNER NO MOVE
Details
The block next to corner chamfering/ corner rounding is not a travel command.
Remedy
- Replace the block succeeding the corner chamfering/ corner rounding command by G01
command.
P383 CORNER SHORT
Details
The travel distance in the corner chamfering/corner rounding command was shorter than the
value in the corner chamfering/corner rounding command.
Remedy
- Set the smaller value for the corner chamfering/corner rounding than the travel distance.
P384 CORNER SHORT
Details
The travel distance in the following block in the corner chamfering/corner rounding command
was shorter than the value in the corner chamfering/corner rounding command.
Remedy
- Set the smaller value for the corner chamfering/corner rounding than the travel distance in
the following block.
P385 G0 G33 IN CONR
Details
A block with corner chamfering/corner rounding was given during G00 or G33 modal.
Remedy
- Correct the program.
P390 NO GEOMETRIC
Details
A geometric command was issued though it is out of specifications.
Remedy
- Check the specifications.
P391 NO GEOMETRIC 2
Details
There are no geometric IB specifications.
Remedy
- Check the specifications.
P392 LES AGL (GEOMT)
Details
The angular difference between the geometric line and line is 1° or less.
Remedy
- Correct the geometric angle.
P393 INC ERR (GEOMT)
Details
The second geometric block has a command with an incremental value.
Remedy
- Issue a command with an absolute value in the second geometric block.
P394 NO G01 (GEOMT)
Details
The second geometric block contains no linear command.
Remedy
- Issue the G01 command.
P395 NO ADRS (GEOMT)
Details
The geometric format is invalid.
Remedy
- Correct the program.
P396 PL CHG. (GEOMT)
Details
A plane switching command was issued during geometric command processing.
Remedy
- Complete the plane switching command before geometric command processing.
P397 ARC ERR (GEOMT)
Details
In geometric IB, the circular arc end point does not contact or cross the next block start point.
Remedy
- Correct the geometric circular arc command and the preceding and following commands.
P398 NO GEOMETRIC1B
Details
A geometric command was issued though the geometric IB specifications are not provided.
Remedy
- Check the specifications.
P420 NO PARAM IN
Details
Parameter input by program (G10) was commanded though it is out of specifications.
Remedy
- Check the specifications.