Specifications
Table Of Contents
- Front cover
- Trademarks
- Contents
- Remedy and measure after a report of error
- I Alarms
- 1. Operation Errors (M)
- 2. Stop Codes (T)
- 3. Servo/Spindle Alarms (S)
- 4. MCP Alarms (Y)
- 5. Safety Observation Alarms (Y)
- 6. System Alarms (Z)
- 7. Absolute Position Detection System Alarms (Z7*)
- 8. Emergency Stop Alarms (EMG)
- 9. Auxiliary Axis Operation Errors (M)
- 10. CNCCPU-side Safety Sequence Alarm(U)
- 11. Multi CPU Errors (A)
- 12. Network Errors (L)
- 13. Program Errors (P)
- II Parameters
- 1. Machining Parameters
- 2. Base Specifications Parameters
- 3. Axis Specifications Parameters
- 4. Servo Parameters
- 5. Spindle Parameters
- 6. Multi-CPU Parameters
- 7. FL-net Parameters
- 8. DeviceNet Parameters
- 9. Machine Error Compensation Parameters
- 10. PLC Parameters
- 11. Macro List
- 12. Position Switches
- 13. PLC Axis Indexing Parameters
- III PLC Devices
- Revision History
- Back cover

I Alarms
Program Errors (P)
I - 75
P179 GROUP NO. ILL.
Details
- A duplicate group No. was found at the registration of the tool life management data with
G10.
- A group No. that was not registered was designated during the T****99 command.
- An M code command, which must be issued as a single command, coexists in the same
block as that of another M code command.
- The M code commands set in the same group exist in the same block.
Remedy
- Register the tool life data once for one group: commanding with a duplicate group No. is not
allowed.
- Correct to the group No.
P180 NO BORING CYC.
Details
A fixed cycle command (G72 - G89) was issued though it is out of specifications.
Remedy
- Check the specifications.
- Correct the program.
P181 NO S-CMD (TAP)
Details
Spindle rotation speed (S) has not been commanded in synchronous tapping.
Remedy
- Command the spindle rotation speed (S) in synchronous tapping.
- When "#8125 Check Scode in G84" is set to "1", enter the S command in the same block
where the synchronous tapping command is issued.
P182 SYN TAP ERROR
Details
- Connection to the main spindle unit was not established.
- The synchronous tapping was attempted with the spindle not serially connected under the
multiple-spindle control I.
Remedy
- Check connection to the main spindle.
- Check that the main spindle encoder exists.
- Set 1 to the parameter #3024 (sout).
P183 PTC/THD No.
Details
The pitch or number of threads has not been commanded in the tap cycle of a fixed cycle for
drilling command.
Remedy
- Specify the pitch data and the number of threads by F or E command.
P184 NO PTC/THD CMD
Details
- The pitch or the number of threads per inch is illegal in the tap cycle of the fixed cycle for
drilling command.
- The pitch is too small for the spindle rotation speed.
- The thread number is too large for the spindle rotation speed.
Remedy
- Correct the pitch or the number of threads per inch.
P187 Tap SP clamp 0
Details
The external spindle speed clamp signal was turned ON without setting the tapping spindle's
external spindle speed when commanding the synchronous tapping.
Remedy
- Set the external spindle speed clamp speed parameter.
- Turn the external spindle speed clamp signal OFF.
P190 NO CUTTING CYC
Details
A lathe cutting cycle command was issued though it is out of specifications.
Remedy
- Check the specification.
- Delete the lathe cutting cycle command.
P191 TAPER LENG ERR
Details
In the lathe cutting cycle, the specified length of taper section is illegal.
Remedy
- Set the smaller radius value than the axis travel amount in the lathe cycle command.
P192 CHAMFERING ERR
Details
Chamfering in the thread cutting cycle is illegal.
Remedy
- Set a chamfering amount not exceeding the cycle.
P200 NO MRC CYC SPC
Details
The compound type fixed cycle for turning machining I (G70 to G73) was commanded though
it is out of specifications.
Remedy
- Check the specifications.