Specifications
Table Of Contents
- Front cover
- Trademarks
- Contents
- Remedy and measure after a report of error
- I Alarms
- 1. Operation Errors (M)
- 2. Stop Codes (T)
- 3. Servo/Spindle Alarms (S)
- 4. MCP Alarms (Y)
- 5. Safety Observation Alarms (Y)
- 6. System Alarms (Z)
- 7. Absolute Position Detection System Alarms (Z7*)
- 8. Emergency Stop Alarms (EMG)
- 9. Auxiliary Axis Operation Errors (M)
- 10. CNCCPU-side Safety Sequence Alarm(U)
- 11. Multi CPU Errors (A)
- 12. Network Errors (L)
- 13. Program Errors (P)
- II Parameters
- 1. Machining Parameters
- 2. Base Specifications Parameters
- 3. Axis Specifications Parameters
- 4. Servo Parameters
- 5. Spindle Parameters
- 6. Multi-CPU Parameters
- 7. FL-net Parameters
- 8. DeviceNet Parameters
- 9. Machine Error Compensation Parameters
- 10. PLC Parameters
- 11. Macro List
- 12. Position Switches
- 13. PLC Axis Indexing Parameters
- III PLC Devices
- Revision History
- Back cover

I Alarms
Network Errors (L)
I - 66
L11 DN INIT. ERR. 2 06 (Error-detected module I/O No.)
Details
A deviceNet initialization error has occurred. The error-detected node No. is FEH.
- A slave node having the same node No. as the node No. of the local node is set in the buffer
memory.
"Error-detected module I/O No." shows the error-detected module I/O No. with the last digit
removed.
Remedy
- Set non-duplicate node Nos. in all nodes.
L11 DN INIT. ERR. 2 07 (Error-detected module I/O No.)
Details
A deviceNet initialization error has occurred. The error-detected node No. is FEH.
- No slave node has been set.
"Error-detected module I/O No." shows the error-detected module I/O No. with the last digit
removed.
Remedy
- Set at least one slave node.
L11 DN INIT. ERR. 2 08 (Error-detected module I/O No.)
Details
A deviceNet initialization error has occurred. The error-detected node No. is FEH.
- The total input data length of all slave nodes is too long.
"Error-detected module I/O No." shows the error-detected module I/O No. with the last digit
removed.
Remedy
- Reduce the total data length of all slave nodes to 512 bytes or less.
L11 DN INIT. ERR. 2 09 (Error-detected module I/O No.)
Details
A deviceNet initialization error has occurred. The error-detected node No. is FEH.
- The total output data length of all slave nodes is too long.
"Error-detected module I/O No." shows the error-detected module I/O No. with the last digit
removed.
Remedy
- Reduce the total data length of all slave nodes to 512 bytes or less.
L11 DN INIT. ERR. 2 0A (Error-detected module I/O No.)
Details
A deviceNet initialization error has occurred. The error-detected node No. is FEH.
- The watchdog timeout action value in a parameter is invalid.
"Error-detected module I/O No." shows the error-detected module I/O No. with the last digit
removed.
Remedy
- Set it to one of the following: 0000H, 0001H, 0002H,
or 0003H.
L11 DN INIT. ERR. 2 0B (Error-detected module I/O No.)
Details
A deviceNet initialization error has occurred. The error-detected node No. is FEH.
- The expected packet rate value in the buffer memory is smaller than the production inhibit
time value.
"Error-detected module I/O No." shows the error-detected module I/O No. with the last digit
removed.
Remedy
- Change the value so that the expected packet rate is greater than or equal to the production
inhibit time value.
L11 DN INIT. ERR. 2 0C (Error-detected module I/O No.)
Details
A deviceNet initialization error has occurred. The error-detected node No. is FEH.
- Flash ROM checksum error (parameter area for the master function)
"Error-detected module I/O No." shows the error-detected module I/O No. with the last digit
removed.
Remedy
- Save the parameters again.
- Do not turn OFF the power or reset while saving the parameters.
L11 DN INIT. ERR. 2 0D (Error-detected module I/O No.)
Details
A deviceNet initialization error has occurred. The error-detected node No. is FEH.
- Flash ROM checksum error (parameter area for the slave function)
"Error-detected module I/O No." shows the error-detected module I/O No. with the last digit
removed.
Remedy
- Save the parameters again.
- Do not turn OFF the power or reset while saving the parameters.
L11 DN INIT. ERR. 2 0E (Error-detected module I/O No.)
Details
A deviceNet initialization error has occurred. The error-detected node No. is FEH.
- Flash ROM checksum error (auto communication start setting area)
"Error-detected module I/O No." shows the error-detected module I/O No. with the last digit
removed.
Remedy
- Save the parameters again.
- Do not turn OFF the power or reset while saving the parameters.