Specifications
Table Of Contents
- Front cover
- Trademarks
- Contents
- Remedy and measure after a report of error
- I Alarms
- 1. Operation Errors (M)
- 2. Stop Codes (T)
- 3. Servo/Spindle Alarms (S)
- 4. MCP Alarms (Y)
- 5. Safety Observation Alarms (Y)
- 6. System Alarms (Z)
- 7. Absolute Position Detection System Alarms (Z7*)
- 8. Emergency Stop Alarms (EMG)
- 9. Auxiliary Axis Operation Errors (M)
- 10. CNCCPU-side Safety Sequence Alarm(U)
- 11. Multi CPU Errors (A)
- 12. Network Errors (L)
- 13. Program Errors (P)
- II Parameters
- 1. Machining Parameters
- 2. Base Specifications Parameters
- 3. Axis Specifications Parameters
- 4. Servo Parameters
- 5. Spindle Parameters
- 6. Multi-CPU Parameters
- 7. FL-net Parameters
- 8. DeviceNet Parameters
- 9. Machine Error Compensation Parameters
- 10. PLC Parameters
- 11. Macro List
- 12. Position Switches
- 13. PLC Axis Indexing Parameters
- III PLC Devices
- Revision History
- Back cover

I Alarms
Multi CPU Errors (A)
I - 58
A01 MULTI CPU ERROR 3103
Details
- Although the number of modules has been set to 1 or greater number in the Ethernet module
count parameter setting, the number of actually mounted module is 0.
- The head I/O No. of the Ethernet network parameter differs from the I/O No. of the actually
mounted module.
Remedy
- Correct and write the network parameters.
- If the error occurs after correction, it suggests a hardware fault. Contact your local service
center.
Details
- In a multiple CPU system, the Q series Ethernet interface module under control of another
station is specified to the head I/O number of the Ethernet network parameter.
Remedy
- Delete the Ethernet network parameter of MELSECNET/H module under control of another
station.
- Change the setting to the head I/O number of the MELSECNET/H module under control of
the host station.
A01 MULTI CPU ERROR 3104
Details
- The Ethernet and MELSECNET/H use the same network number.
- The network number, station number or group number set in the network parameter is out
of range.
- The specified I/O No. is outside the range of the used CPU module.
- The Ethernet-specific parameter setting is not normal.
Remedy
- Correct and write the network parameters.
- If the error occurs after correction, it suggests a hardware fault. Contact your local service
center.
A01 MULTI CPU ERROR 3105
Details
- Though the number of CC-Link modules set in the network parameters is one or more, the
number of actually mounted modules is zero.
- The head I/O number in the common parameters is different from that of the actually mount-
ed module.
- The station type of the CC-Link module count setting parameters is different from that of the
actually mounted station.
Remedy
- Correct and write the network parameters.
- If the error occurs after correction, it suggests a hardware fault. Contact your local service
center.
Details
- In a multiple CPU system, the Q series CC-Link module under control of another station is
specified as the head I/O number of the CC-Link network parameter.
Remedy
- Delete the CC-Link network parameter of the Q series CC-Link module under control of an-
other station.
- Change the setting to the head I/O number of the Q series CC-Link module under control of
the host station.
A01 MULTI CPU ERROR 3106
Details
- The CC-Link link refresh range exceeded the file register capacity.
Remedy
- Change the file register file for the one refresh-enabled in the whole range.
Details
- The network refresh parameter for CC-Link is out of range.
Remedy
- Check the parameter setting.
A01 MULTI CPU ERROR 3107
Details
- The CC-Link parameter setting is incorrect.
- The set mode is not allowed for the version of the mounted CC-Link module.
Remedy
- Check the parameter setting.
A01 MULTI CPU ERROR 3300
Details
- The head I/O number in the intelligent function module parameter set on GX Configurator
differs from the actual I/O number.
Remedy
- Check the parameter setting.
A01 MULTI CPU ERROR 3301
Details
- The refresh setting of the intelligent function module exceeded the file register capacity.
Remedy
- Change the file register file for the one which allows refresh in the whole range.
Details
- The intelligent function module's refresh parameter setting is outside the available range.
Remedy
- Check the parameter setting.
A01 MULTI CPU ERROR 3302
Details
- The intelligent function module's refresh parameter is abnormal.
Remedy
- Check the parameter setting.