I Alarms
Multi CPU Errors (A)
I - 48
11. Multi CPU Errors (A)
For alarms which are not explained below, refer to the error code list in "QCPU User's Manual (Hardware
Design, Maintenance and Inspection)" (SH(NA)-080483).
A01 MULTI CPU ERROR 1000
Details
Run mode suspended or failure of CPU module.
- Malfunctioning due to noise or other reason
- Hardware fault
Remedy
- Take noise reduction measures.
- Reset and restart the CPU module.
If the same error is displayed again, this suggests a CPU module hardware fault. Contact
your local service center.
A01 MULTI CPU ERROR 1001
Details
Run mode suspended or failure of CPU module.
- Malfunctioning due to noise or other reason
- Hardware fault
Remedy
- Take noise reduction measures.
- Reset and restart the CPU module.
If the same error is displayed again, this suggests a CPU module hardware fault. Contact
your local service center.
A01 MULTI CPU ERROR 1002
Details
Run mode suspended or failure of CPU module.
- Malfunctioning due to noise or other reason
- Hardware fault
Remedy
- Take noise reduction measures.
- Reset and restart the CPU module.
If the same error is displayed again, this suggests a CPU module hardware fault. Contact
your local service center.
A01 MULTI CPU ERROR 1003
Details
Run mode suspended or failure of CPU module.
- Malfunctioning due to noise or other reason
- Hardware fault
Remedy
- Take noise reduction measures.
- Reset and restart the CPU module.
If the same error is displayed again, this suggests a CPU module hardware fault. Contact
your local service center.
A01 MULTI CPU ERROR 1004
Details
Run mode suspended or failure of CPU module.
- Malfunctioning due to noise or other reason
- Hardware fault
Remedy
- Take noise reduction measures.
- Reset and restart the CPU module.
If the same error is displayed again, this suggests a CPU module hardware fault. Contact
your local service center.
A01 MULTI CPU ERROR 1005
Details
Run mode suspended or failure of CPU module.
- Malfunctioning due to noise or other reason
- Hardware fault
Remedy
- Take noise reduction measures.
- Reset and restart the CPU module.
If the same error is displayed again, this suggests a CPU module hardware fault. Contact
your local service center.
A01 MULTI CPU ERROR 1006
Details
Run mode suspended or failure of CPU module.
- Malfunctioning due to noise or other reason
- Hardware fault
Remedy
- Take noise reduction measures.
- Reset and restart the CPU module.
If the same error is displayed again, this suggests a CPU module hardware fault. Contact
your local service center.
A01 MULTI CPU ERROR 1009
Details
- A failure is detected on the power supply module, CPU module, base unit or extension cable.
Remedy
- Reset and restart the CPU module.
If the same error is detected again, it is considered that the power supply module, CPU mod-
ule, base unit or extension cable is faulty. Contact your local service center.