Specifications

Table Of Contents
II Parameters
Position Switches
II - 162
#7712 <dog1> Imaginary dog position 1 PSW22
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X67D
Part system 2 device: X6FD
---Setting range---
-99999.999 to 99999.999 (0.001mm)
#7713 <dog2> Imaginary dog position 2 PSW22
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X67D
Part system 2 device: X6FD
---Setting range---
-99999.999 to 99999.999 (0.001mm)
#7714 <check> Selection of area check method PSW22
When position switch area checking at high speed is selected, specify the mode of area
checking, i.e., whether to use the command type machine position or detector feedback
position, for each position switch point.
0: Use the command type machine position as the machine position for position switch
area checking.
1: Use the detector feedback position as the machine position for position switch area
checking.
#7721 <axis> Axis name PSW23
Specify the name of the axis for which a position switch is provided.
---Setting range---
NC axis: axis name (X, Y, Z, U, V, W, A, B, or C)
#7722 <dog1> Imaginary dog position 1 PSW23
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X67E
Part system 2 device: X6FE
---Setting range---
-99999.999 to 99999.999 (0.001mm)
#7723 <dog2> Imaginary dog position 2 PSW23
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X67E
Part system 2 device: X6FE
---Setting range---
-99999.999 to 99999.999 (0.001mm)
#7724 <check> Selection of area check method PSW23
When position switch area checking at high speed is selected, specify the mode of area
checking, i.e., whether to use the command type machine position or detector feedback
position, for each position switch point.
0: Use the command type machine position as the machine position for position switch
area checking.
1: Use the detector feedback position as the machine position for position switch area
checking.
#7731 <axis> Axis name PSW24
Specify the name of the axis for which a position switch is provided.
---Setting range---
NC axis: axis name (X, Y, Z, U, V, W, A, B, or C)
#7732 <dog1> Imaginary dog position 1 PSW24
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X67F
Part system 2 device: X6FF
---Setting range---
-99999.999 to 99999.999 (0.001mm)
#7733 <dog2> Imaginary dog position 2 PSW24
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X67F
Part system 2 device: X6FF
---Setting range---
-99999.999 to 99999.999 (0.001mm)
#7734 <check> Selection of area check method PSW24
When position switch area checking at high speed is selected, specify the mode of area
checking, i.e., whether to use the command type machine position or detector feedback
position, for each position switch point.
0: Use the command type machine position as the machine position for position switch
area checking.
1: Use the detector feedback position as the machine position for position switch area
checking.