Specifications
Table Of Contents
- Front cover
- Trademarks
- Contents
- Remedy and measure after a report of error
- I Alarms
- 1. Operation Errors (M)
- 2. Stop Codes (T)
- 3. Servo/Spindle Alarms (S)
- 4. MCP Alarms (Y)
- 5. Safety Observation Alarms (Y)
- 6. System Alarms (Z)
- 7. Absolute Position Detection System Alarms (Z7*)
- 8. Emergency Stop Alarms (EMG)
- 9. Auxiliary Axis Operation Errors (M)
- 10. CNCCPU-side Safety Sequence Alarm(U)
- 11. Multi CPU Errors (A)
- 12. Network Errors (L)
- 13. Program Errors (P)
- II Parameters
- 1. Machining Parameters
- 2. Base Specifications Parameters
- 3. Axis Specifications Parameters
- 4. Servo Parameters
- 5. Spindle Parameters
- 6. Multi-CPU Parameters
- 7. FL-net Parameters
- 8. DeviceNet Parameters
- 9. Machine Error Compensation Parameters
- 10. PLC Parameters
- 11. Macro List
- 12. Position Switches
- 13. PLC Axis Indexing Parameters
- III PLC Devices
- Revision History
- Back cover

II Parameters
Position Switches
II - 159
【#7632】 <dog1> Imaginary dog position 1 PSW14
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X66D
Part system 2 device: X6ED
---Setting range---
-99999.999 to 99999.999 (0.001mm)
【#7633】 <dog2> Imaginary dog position 2 PSW14
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X66D
Part system 2 device: X6ED
---Setting range---
-99999.999 to 99999.999 (0.001mm)
【#7634】 <check> Selection of area check method PSW14
When position switch area checking at high speed is selected, specify the mode of area
checking, i.e., whether to use the command type machine position or detector feedback
position, for each position switch point.
0: Use the command type machine position as the machine position for position switch
area checking.
1: Use the detector feedback position as the machine position for position switch area
checking.
【#7641】 <axis> Axis name PSW15
Specify the name of the axis for which a position switch is provided.
---Setting range---
NC axis: axis name (X, Y, Z, U, V, W, A, B, or C)
PLC axis: PLC No. (1 to 8)
【#7642】 <dog1> Imaginary dog position 1 PSW15
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X66E
Part system 2 device: X6EE
---Setting range---
-99999.999 to 99999.999 (0.001mm)
【#7643】 <dog2> Imaginary dog position 2 PSW15
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X66E
Part system 2 device: X6EE
---Setting range---
-99999.999 to 99999.999 (0.001mm)
【#7644】 <check> Selection of area check method PSW15
When position switch area checking at high speed is selected, specify the mode of area
checking, i.e., whether to use the command type machine position or detector feedback
position, for each position switch point.
0: Use the command type machine position as the machine position for position switch
area checking.
1: Use the detector feedback position as the machine position for position switch area
checking.
【#7651】 <axis> Axis name PSW16
Specify the name of the axis for which a position switch is provided.
---Setting range---
NC axis: axis name (X, Y, Z, U, V, W, A, B, or C)
PLC axis: PLC No. (1 to 8)
【#7652】 <dog1> Imaginary dog position 1 PSW16
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X66F
Part system 2 device: X6EF
---Setting range---
-99999.999 to 99999.999 (0.001mm)
【#7653】 <dog2> Imaginary dog position 2 PSW16
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X66F
Part system 2 device: X6EF
---Setting range---
-99999.999 to 99999.999 (0.001mm)