#7574 <check> Selection of area check method PSW8
When position switch area checking at high speed is selected, specify the mode of area
checking, i.e., whether to use the command type machine position or detector feedback
position, for each position switch point.
0: Use the command type machine position as the machine position for position switch
area checking.
1: Use the detector feedback position as the machine position for position switch area
checking.
#7581 <axis> Axis name PSW9
Specify the name of the axis for which a position switch is provided.
---Setting range---
NC axis: axis name (X, Y, Z, U, V, W, A, B, or C)
PLC axis: PLC No. (1 to 8)
#7582 <dog1> Imaginary dog position 1 PSW9
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X668
Part system 2 device: X6E8
---Setting range---
-99999.999 to 99999.999 (0.001mm)
#7583 <dog2> Imaginary dog position 2 PSW9
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X668
Part system 2 device: X6E8
---Setting range---
-99999.999 to 99999.999 (0.001mm)
#7584 <check> Selection of area check method PSW9
When position switch area checking at high speed is selected, specify the mode of area
checking, i.e., whether to use the command type machine position or detector feedback
position, for each position switch point.
0: Use the command type machine position as the machine position for position switch
area checking.
1: Use the detector feedback position as the machine position for position switch area
checking.
#7591 <axis> Axis name PSW10
Specify the name of the axis for which a position switch is provided.
---Setting range---
NC axis: axis name (X, Y, Z, U, V, W, A, B, or C)
PLC axis: PLC No. (1 to 8)
#7592 <dog1> Imaginary dog position 1 PSW10
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X669
Part system 2 device: X6E9
---Setting range---
-99999.999 to 99999.999 (0.001mm)
#7593 <dog2> Imaginary dog position 2 PSW10
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X669
Part system 2 device: X6E9
---Setting range---
-99999.999 to 99999.999 (0.001mm)
#7594 <check> Selection of area check method PSW10
When position switch area checking at high speed is selected, specify the mode of area
checking, i.e., whether to use the command type machine position or detector feedback
position, for each position switch point.
0: Use the command type machine position as the machine position for position switch
area checking.
1: Use the detector feedback position as the machine position for position switch area
checking.
#7601 <axis> Axis name PSW11
Specify the name of the axis for which a position switch is provided.
---Setting range---
NC axis: axis name (X, Y, Z, U, V, W, A, B, or C)
PLC axis: PLC No. (1 to 8)
#7602 <dog1> Imaginary dog position 1 PSW11
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X66A
Part system 2 device: X6EA
---Setting range---
-99999.999 to 99999.999 (0.001mm)