Specifications

Table Of Contents
II Parameters
Position Switches
II - 155
#7523 <dog2> Imaginary dog position 2 PSW3
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X662
Part system 2 device: X6E2
---Setting range---
-99999.999 to 99999.999 (0.001mm)
#7524 <check> Selection of area check method PSW3
When position switch area checking at high speed is selected, specify the mode of area
checking, i.e., whether to use the command type machine position or detector feedback
position, for each position switch point.
0: Use the command type machine position as the machine position for position switch
area checking.
1: Use the detector feedback position as the machine position for position switch area
checking.
#7531 <axis> Axis name PSW4
Specify the name of the axis for which a position switch is provided.
---Setting range---
NC axis: axis name (X, Y, Z, U, V, W, A, B, or C)
PLC axis: PLC No. (1 to 8)
#7532 <dog1> Imaginary dog position 1 PSW4
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X663
Part system 2 device: X6E3
---Setting range---
-99999.999 to 99999.999 (0.001mm)
#7533 <dog2> Imaginary dog position 2 PSW4
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X663
Part system 2 device: X6E3
---Setting range---
-99999.999 to 99999.999 (0.001mm)
#7534 <check> Selection of area check method PSW4
When position switch area checking at high speed is selected, specify the mode of area
checking, i.e., whether to use the command type machine position or detector feedback
position, for each position switch point.
0: Use the command type machine position as the machine position for position switch
area checking.
1: Use the detector feedback position as the machine position for position switch area
checking.
#7541 <axis> Axis name PSW5
Specify the name of the axis for which a position switch is provided.
---Setting range---
NC axis: axis name (X, Y, Z, U, V, W, A, B, or C)
PLC axis: PLC No. (1 to 8)
#7542 <dog1> Imaginary dog position 1 PSW5
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X664
Part system 2 device: X6E4
---Setting range---
-99999.999 to 99999.999 (0.001mm)
#7543 <dog2> Imaginary dog position 2 PSW5
When the machine enters the range between imaginary dog positions 1 and 2, a signal is
output to the PLC.
Part system 1 device: X664
Part system 2 device: X6E4
---Setting range---
-99999.999 to 99999.999 (0.001mm)
#7544 <check> Selection of area check method PSW5
When position switch area checking at high speed is selected, specify the mode of area
checking, i.e., whether to use the command type machine position or detector feedback
position, for each position switch point.
0: Use the command type machine position as the machine position for position switch
area checking.
1: Use the detector feedback position as the machine position for position switch area
checking.
#7551 <axis> Axis name PSW6
Specify the name of the axis for which a position switch is provided.
---Setting range---
NC axis: axis name (X, Y, Z, U, V, W, A, B, or C)