Specifications

Table Of Contents
II Parameters
Macro List
II - 147
#7033 M[04] Program No.
Set the No. of the program to be called out.
---Setting range---
1 to 99999999
#7041 M[05] Code
Set the M code used for calling out the macro with the M command.
This is valid when "#1195 Mmac" is set to "1".
---Setting range---
0 to 9999
#7042 M[05] Type
Set the macro call out type.
0: M98 P △△△△ ; and equivalent value call
1: G65 P △△△△ ; and equivalent value call
2: G66 P △△△△ ; and equivalent value call
3: G66.1 P △△△△ ; and equivalent value call
others: M98 P △△△ ; and equivalent value call
#7043 M[05] Program No.
Set the No. of the program to be called out.
---Setting range---
1 to 99999999
#7051 M[06] Code
Set the M code used for calling out the macro with the M command.
This is valid when "#1195 Mmac" is set to "1".
---Setting range---
0 to 9999
#7052 M[06] Type
Set the macro call out type.
0: M98 P △△△△ ; and equivalent value call
1: G65 P △△△△ ; and equivalent value call
2: G66 P △△△△ ; and equivalent value call
3: G66.1 P △△△△ ; and equivalent value call
others: M98 P △△△ ; and equivalent value call
#7053 M[06] Program No.
Set the No. of the program to be called out.
---Setting range---
1 to 99999999
#7061 M[07] Code
Set the M code used for calling out the macro with the M command.
This is valid when "#1195 Mmac" is set to "1".
---Setting range---
0 to 9999
#7062 M[07] Type
Set the macro call out type.
0: M98 P △△△△ ; and equivalent value call
1: G65 P △△△△ ; and equivalent value call
2: G66 P △△△△ ; and equivalent value call
3: G66.1 P △△△△ ; and equivalent value call
others: M98 P △△△ ; and equivalent value call
#7063 M[07] Program No.
Set the No. of the program to be called out.
---Setting range---
1 to 99999999
#7071 M[08] Code
Set the M code used for calling out the macro with the M command.
This is valid when "#1195 Mmac" is set to "1".
---Setting range---
0 to 9999
#7072 M[08] Type
Set the macro call out type.
0: M98 P △△△△ ; and equivalent value call
1: G65 P △△△△ ; and equivalent value call
2: G66 P △△△△ ; and equivalent value call
3: G66.1 P △△△△ ; and equivalent value call
others: M98 P △△△ ; and equivalent value call