Specifications

Table Of Contents
II Parameters
PLC Parameters
II - 145
10. PLC Parameters
#6000 - 6015 T000-T015 10ms adding timer <10ms>
Set the time for the timer used in the PLC program (ladder).
(Note) This setting value is valid when parameter "#6449 bit0" in the following "[BIT
SELECT]" is set to "0".
---Setting range---
0 to 32767 ( x 10ms)
#6016 - 6095 T016-T095 100ms adding timer <100ms>
Set the time for the timer used in the PLC program (ladder).
(Note) This setting value is valid when parameter "#6449 bit0" in the following "[BIT
SELECT]" is set to "0".
---Setting range---
0 to 32767 ( x 100ms)
#6096 - 6103 T096-T103 100ms cumulative timer <100msINC>
Set the time for the timer used in the PLC program (ladder).
(Note) This setting value is valid when parameter "#6449 bit0" in the following "[BIT
SELECT]" is set to "0".
---Setting range---
0 to 32767 ( x 100ms)
#6200 - 6223 C000-C023 Counter
Set the time for the counter used in the PLC program (ladder).
(Note) This setting value is valid when parameter "#6449 bit1" in the following "[BIT
SELECT]" is set to "0".
---Setting range---
0 to 32767
#6301 - 6348 R4500,R4501 - R4594,R4595 PLC constant
Set the value to be set in the data type R register used in the PLC program (ladder).
Even if the data is set in the R register that corresponds to the PLC side when this
parameter is displayed. the screen will not change.Enter a different screen once. and then
select this screen again.
Note that some parameters have limited uses.
---Setting range---
-99999999 to 99999999
#6401,6402 - 6495,6496 R4600-Low,R4600-High - R4647-Low,R4647-High Bit selection
This is the bit type parameter used in the PLC program (ladder).
Even if the data is set in the R register that corresponds to the PLC side when this
parameter is displayed, the screen will not change. Enter a different screen once, and then
select this screen again.
Note that some parameters have limited uses.
0 : OFF
1 : ON
#6449
bit7: Control unit overheat detected
Designate whether to detect the control unit overheat alarm or not.
0 : Detect
1 : Not detect
#6451
bit3: Key data via PLC
Validates the key data in the shared device G10212, which is set by the sequence
programs.
If this parameter is valid, the key data, read out from the shared device on NC (G10208),
must be returned to the shared device on PLC (G10212) even if the data will not be
changed by sequence programs.
Unless the data is returned to PLC, keys are not available.
When the programs stop on PLC (including when STOP is selected with the RUN/STOP
switch), key data is not accessed via PLC.
0 : Invalid
1 : Valid
#6454
bit0: Macro interface for respective part systems
Designate whether to use the macro interface for respective part systems or not.
0 : Conventional macro interface common to part systems.
1 : Available to respective part systems.