Specifications

Table Of Contents
II Parameters
DeviceNet Parameters
II - 139
#29070(PR) Obstacle Status PLC side Device
Each node obstacle status read device
Set a device to store the following data:
Slave node communication obstacle status is stored.
When the corresponding node communication error information read is executed in the
message communication, the corresponding bit will be turned OFF.
Bit settings: 0: No obstacle information / 1: Obstacle information exists
<1st word>
bit0: 0th slave node
bit1: 1st slave node
:
bitF: 15th slave node
<2nd word>
bit0: 16th slave node
bit1: 17th slave node
:
bitF: 31st slave node
<3rd word>
bit0: 32nd slave node
bit1: 33rd slave node
:
bitF: 47th slave node
<4th word>
bit0: 48th slave node
bit1: 49th slave node
:
bitF: 63rd slave node
---Setting range---
Within the number of device points set in the PC parameter's device setting.
#29071(PR) Down Node Detect. Disable St. Module side Transfer Cont
Down node detection read word count
Set a read word count of the data where the down node detection disabled status is saved.
The standard setting is "4".
---Setting range---
1 to 4
#29072(PR) Down Node Detect. Disable St. PLC side Device
Down node detection read device
Set a device to store the following data:
The down node detection disabled status is stored.
Bit settings
0: The slave down signal (X04) is turned ON when the corresponding slave node is
down.
1: The slave down signal (X04) is NOT turned ON when the corresponding slave node is
down.
<1st word>
bit0: 0th slave node
bit1: 1st slave node
:
bitF: 15th slave node
<2nd word>
bit0: 16th slave node
bit1: 17th slave node
:
bitF: 31st slave node
<3rd word>
bit0: 32nd slave node
bit1: 33rd slave node
:
bitF: 47th slave node
<4th word>
bit0: 48th slave node
bit1: 49th slave node
:
bitF: 63rd slave node
---Setting range---
Within the number of device points set in the PC parameter's device setting.
#29073(PR) Present Link Scan Time PLC side Device Present link scan time
Set the device where the current link scan time is stored. (unit: ms)
---Setting range---
Within the number of device points set in the PC parameter's device setting.
#29074(PR) Minimum Link Scan Time PLC side Device Minimum link scan time
Set the device where the minimum link scan time since the power has been turned ON is
stored. (unit: ms)
---Setting range---
Within the number of device points set in the PC parameter's device setting.
#29075(PR) Maximum Link Scan Time PLC side Device Maximum link scan time
Set the device where the maximum link scan time since the power has been turned ON is
stored. (unit: ms)
---Setting range---
Within the number of device points set in the PC parameter's device setting.