Specifications
Table Of Contents
- Front cover
- Trademarks
- Contents
- Remedy and measure after a report of error
- I Alarms
- 1. Operation Errors (M)
- 2. Stop Codes (T)
- 3. Servo/Spindle Alarms (S)
- 4. MCP Alarms (Y)
- 5. Safety Observation Alarms (Y)
- 6. System Alarms (Z)
- 7. Absolute Position Detection System Alarms (Z7*)
- 8. Emergency Stop Alarms (EMG)
- 9. Auxiliary Axis Operation Errors (M)
- 10. CNCCPU-side Safety Sequence Alarm(U)
- 11. Multi CPU Errors (A)
- 12. Network Errors (L)
- 13. Program Errors (P)
- II Parameters
- 1. Machining Parameters
- 2. Base Specifications Parameters
- 3. Axis Specifications Parameters
- 4. Servo Parameters
- 5. Spindle Parameters
- 6. Multi-CPU Parameters
- 7. FL-net Parameters
- 8. DeviceNet Parameters
- 9. Machine Error Compensation Parameters
- 10. PLC Parameters
- 11. Macro List
- 12. Position Switches
- 13. PLC Axis Indexing Parameters
- III PLC Devices
- Revision History
- Back cover

II Parameters
FL-net Parameters
II - 132
【#29026(PR)】 Cyclic Data:Area1 Other Node Area Module side Transfer Cont.
Cyclic data: Area1 Other node area Module side transfer word count
Set the word count of the data used for reading the other node data in cyclic data area 1 (bit
area).
The standard setting is "512".
(Note) An error will occur when the buffer offset value exceeds "512" after the transfer size
is added.
---Setting range---
1 to 512
【#29027(PR)】 Cyclic Data:Area1 Other Node Area Module side Buffer off.
Cyclic data: Area1 Other node area Module side buffer offset
Set the head offset of the buffer used for reading the other node data in cyclic data area 1
(bit area).
The standard setting is "0".
(Note) An error will occur when the buffer offset value exceeds "512" after the transfer size
is added.
---Setting range---
0 to 512
【#29028(PR)】 Cyclic Data:Area1 Other Node Area PLC side Device
Cyclic data: Area1 Other node area CPU side device
Set the internal device used for reading the other node data in cyclic data area 1 (bit area).
---Setting range---
Within the number of device points set in the PC parameter's device setting.
【#29029(PR)】 Cyclic Data:Area2 Local Node Area Module side Transfer Cont.
Cyclic data: Area2 Local node area Module side transfer word count
Set the word count of the data which is transferred by the local node to cyclic data area 2
(word area).
The standard setting is "8192".
(Note) An error will occur when the value buffer offset value exceeds "8192" after the
transfer size is added.
---Setting range---
1 to 8192
【#29030(PR)】 Cyclic Data:Area2 Local Node Area Module side Buffer off.
Cyclic data: Area2 Local node area Module side buffer offset
Set the head offset of the buffer for setting the data which is transferred by the local node to
the cyclic data area 2 (word area).
The standard setting is "0".
(Note) An error will occur when the value buffer offset value exceeds "8192" after the
transfer size is added.
---Setting range---
0 to 8192
【#29031(PR)】 Cyclic Data:Area2 Local Node Area PLC side Device
Cyclic data: Area2 Local node area CPU side device
Set the internal device to store the data transferred by the local node to cyclic data area 2
(word area).
---Setting range---
CPU-side device
【#29032(PR)】 Cyclic Data:Area2 Other Node Area Module side Transfer Cont.
Cyclic data: Area2 Other node area Module side transfer word count
Set the word count of the data used for reading the other node data in cyclic data area 2
(word area).
The standard setting is "8192".
(Note) An error will occur when the value buffer offset value exceeds "8192" after the
transfer size is added.
---Setting range---
1 to 8192
【#29033(PR)】 Cyclic Data:Area2 Other Node Area Module side Buffer off.
Cyclic data: Area2 Other node area Module side buffer offset
Set the head offset of the buffer used for reading the other node data in cyclic data area 2
(word area).
The standard setting is "0".
(Note) An error will occur when the value buffer offset value exceeds "8192" after the
transfer size is added.
---Setting range---