Specifications
Table Of Contents
- Front cover
- Trademarks
- Contents
- Remedy and measure after a report of error
- I Alarms
- 1. Operation Errors (M)
- 2. Stop Codes (T)
- 3. Servo/Spindle Alarms (S)
- 4. MCP Alarms (Y)
- 5. Safety Observation Alarms (Y)
- 6. System Alarms (Z)
- 7. Absolute Position Detection System Alarms (Z7*)
- 8. Emergency Stop Alarms (EMG)
- 9. Auxiliary Axis Operation Errors (M)
- 10. CNCCPU-side Safety Sequence Alarm(U)
- 11. Multi CPU Errors (A)
- 12. Network Errors (L)
- 13. Program Errors (P)
- II Parameters
- 1. Machining Parameters
- 2. Base Specifications Parameters
- 3. Axis Specifications Parameters
- 4. Servo Parameters
- 5. Spindle Parameters
- 6. Multi-CPU Parameters
- 7. FL-net Parameters
- 8. DeviceNet Parameters
- 9. Machine Error Compensation Parameters
- 10. PLC Parameters
- 11. Macro List
- 12. Position Switches
- 13. PLC Axis Indexing Parameters
- III PLC Devices
- Revision History
- Back cover

II Parameters
FL-net Parameters
II - 125
7. FL-net Parameters
The parameters with "(PR)" requires the CNC to be turned OFF after the settings. Turn the power OFF and
ON to enable the parameter settings.
【#29001(PR)】 IP Address FL-net module IP address
Set the IP address of the FL-net module.
Input a dot-delimited IP address.
Input a node number in the 4th digit.
The standard setting is "192.168.250.1".
---Setting range---
1st digit: 192 to 223
2nd digit: 0 to 255
3rd digit: 0 to 255
4th digit: 1 to 254
【#29002(PR)】 FL-net Unit Mode FL-net module operation mode
Set the FL-net module operation mode.
The standard setting is "0".
0: Online (Communicates with other nodes)
1: Offline (Disconnects the local node from the network.)
2: Loopback test
3: Hardware test
【#29003(PR)】 Node Name Local node name
Set the local node name.
Setting "0" clears the character string currently set.
---Setting range---
9 or less alphanumeric characters
0: Clear
【#29004(PR)】 Cyclic Data Area1 Addr. Cyclic data area 1: Head address
Set the offset from the head device in cyclic data area 1 (bit area) used by the local node.
The standard setting is "0".
---Setting range---
0000 to 01FF
【#29005(PR)】 Cyclic Data Area1 Size Cyclic data area 1: Size
Set the size of cyclic data area 1 (bit area) used by the local node.
The standard setting is "0".
---Setting range---
0000 to 0200
【#29006(PR)】 Cyclic Data Area2 Addr. Cyclic data area 2: Head address
Set the offset from the head device in cyclic data area 2 (bit area) used by the local node.
The standard setting is "0".
---Setting range---
0000 to 1FFF
【#29007(PR)】 Cyclic Data Area2 Size Cyclic data area 2: Size
Set the size of cyclic data area 2 (word area) used by the local node.
The standard setting is "0".
---Setting range---
0000 to 2000
【#29008(PR)】 Token Watch Time Out Token watch time-out time
Set the token watch time-out time.
The standard setting is "50".
---Setting range---
0 to 65535
【#29009(PR)】 Min. Permissible Frame Duration Minimum permissible frame interval
Set the minimum permissible frame interval.
The standard setting is "0".
---Setting range---
0 to 50
【#29010(PR)】 Message Data Unit Select (0:Word 1:Byte) Message data unit select
Select the data unit in treating message data.
The standard setting is "0".
0: Word unit
1: Byte unit
【#29012(PR)】 Status Data: Bit Area Specified Inform.
Status data: Bit area instruct information area
Set the device to store the following data:
bit9: buffer memory log information area clear
Instructs clearing of the buffer memory log information area (address: A80H to B38H).
0: No clear instruction / 1: Clear instruction
---Setting range---
Within the number of device points set in the PC parameter's device setting.