Specifications

Table Of Contents
II Parameters
FL-net Parameters
II - 125
7. FL-net Parameters
The parameters with "(PR)" requires the CNC to be turned OFF after the settings. Turn the power OFF and
ON to enable the parameter settings.
#29001(PR) IP Address FL-net module IP address
Set the IP address of the FL-net module.
Input a dot-delimited IP address.
Input a node number in the 4th digit.
The standard setting is "192.168.250.1".
---Setting range---
1st digit: 192 to 223
2nd digit: 0 to 255
3rd digit: 0 to 255
4th digit: 1 to 254
#29002(PR) FL-net Unit Mode FL-net module operation mode
Set the FL-net module operation mode.
The standard setting is "0".
0: Online (Communicates with other nodes)
1: Offline (Disconnects the local node from the network.)
2: Loopback test
3: Hardware test
#29003(PR) Node Name Local node name
Set the local node name.
Setting "0" clears the character string currently set.
---Setting range---
9 or less alphanumeric characters
0: Clear
#29004(PR) Cyclic Data Area1 Addr. Cyclic data area 1: Head address
Set the offset from the head device in cyclic data area 1 (bit area) used by the local node.
The standard setting is "0".
---Setting range---
0000 to 01FF
#29005(PR) Cyclic Data Area1 Size Cyclic data area 1: Size
Set the size of cyclic data area 1 (bit area) used by the local node.
The standard setting is "0".
---Setting range---
0000 to 0200
#29006(PR) Cyclic Data Area2 Addr. Cyclic data area 2: Head address
Set the offset from the head device in cyclic data area 2 (bit area) used by the local node.
The standard setting is "0".
---Setting range---
0000 to 1FFF
#29007(PR) Cyclic Data Area2 Size Cyclic data area 2: Size
Set the size of cyclic data area 2 (word area) used by the local node.
The standard setting is "0".
---Setting range---
0000 to 2000
#29008(PR) Token Watch Time Out Token watch time-out time
Set the token watch time-out time.
The standard setting is "50".
---Setting range---
0 to 65535
#29009(PR) Min. Permissible Frame Duration Minimum permissible frame interval
Set the minimum permissible frame interval.
The standard setting is "0".
---Setting range---
0 to 50
#29010(PR) Message Data Unit Select (0:Word 1:Byte) Message data unit select
Select the data unit in treating message data.
The standard setting is "0".
0: Word unit
1: Byte unit
#29012(PR) Status Data: Bit Area Specified Inform.
Status data: Bit area instruct information area
Set the device to store the following data:
bit9: buffer memory log information area clear
Instructs clearing of the buffer memory log information area (address: A80H to B38H).
0: No clear instruction / 1: Clear instruction
---Setting range---
Within the number of device points set in the PC parameter's device setting.