Specifications
Table Of Contents
- Front cover
- Trademarks
- Contents
- Remedy and measure after a report of error
- I Alarms
- 1. Operation Errors (M)
- 2. Stop Codes (T)
- 3. Servo/Spindle Alarms (S)
- 4. MCP Alarms (Y)
- 5. Safety Observation Alarms (Y)
- 6. System Alarms (Z)
- 7. Absolute Position Detection System Alarms (Z7*)
- 8. Emergency Stop Alarms (EMG)
- 9. Auxiliary Axis Operation Errors (M)
- 10. CNCCPU-side Safety Sequence Alarm(U)
- 11. Multi CPU Errors (A)
- 12. Network Errors (L)
- 13. Program Errors (P)
- II Parameters
- 1. Machining Parameters
- 2. Base Specifications Parameters
- 3. Axis Specifications Parameters
- 4. Servo Parameters
- 5. Spindle Parameters
- 6. Multi-CPU Parameters
- 7. FL-net Parameters
- 8. DeviceNet Parameters
- 9. Machine Error Compensation Parameters
- 10. PLC Parameters
- 11. Macro List
- 12. Position Switches
- 13. PLC Axis Indexing Parameters
- III PLC Devices
- Revision History
- Back cover

II Parameters
Spindle Parameters
II - 121
【#13229】 SP229 SFNC9 Spindle function 9
Select the spindle functions.
Functions are allocated to each bit.
Set this in hexadecimal format.
bit F : ssc SLS (Safely Limited Speed) function
0: Disable 1: Enable
bit E :
Not used. Set to "0".
bit D : rps Safely limited speed setting unit
0: Normal 1: 100°/min
bit C : sdt2 Specified speed output digital signal 2 output
0: Normal 1: Enable
bit B-9 :
Not used. Set to "0".
bit 8 : sto Dedicated wiring STO function
Set this parameter to use dedicated wiring STO function.
0: Dedicated wiring STO function unused 1: Dedicated wiring STO function used
bit 7-1 :
Not used. Set to "0".
bit 0 : omrffon OMR-FF control enabled
0: Disable 1: Enable
【#13230】 SP230 SFNC10 Spindle function 10
Select the spindle functions.
Functions are allocated to each bit.
Set this in hexadecimal format.
bit F-C :
Not used. Set to "0".
bit B : pfdsr
Set the spindle stop operation at a power failure when the deceleration and stop function at
power failure is enabled.
Normal (Coast to a stop at power failure) : 0
Deceleration and stop at power failure : 8
bit A-9 :
Not used. Set to "0".
bit 8 : nohis History of communication error alarm between NC and DRV(34,36,38,39)
For C70, set "1".
0: Enable 1: Disable
bit 7 : cse Spindle C axis command speed monitoring function
0: Normal setting (function disabled) 1: Function enabled
bit 6-0 :
Not used. Set to "0".
【#13231】 SP231
Not used. Set to "0000".
【#13232】 SP232
Not used. Set to "0000".
sdt2
rps
ssc
sto
omrffon
cse
nohis