Specifications
Table Of Contents
- Front cover
- Trademarks
- Contents
- Remedy and measure after a report of error
- I Alarms
- 1. Operation Errors (M)
- 2. Stop Codes (T)
- 3. Servo/Spindle Alarms (S)
- 4. MCP Alarms (Y)
- 5. Safety Observation Alarms (Y)
- 6. System Alarms (Z)
- 7. Absolute Position Detection System Alarms (Z7*)
- 8. Emergency Stop Alarms (EMG)
- 9. Auxiliary Axis Operation Errors (M)
- 10. CNCCPU-side Safety Sequence Alarm(U)
- 11. Multi CPU Errors (A)
- 12. Network Errors (L)
- 13. Program Errors (P)
- II Parameters
- 1. Machining Parameters
- 2. Base Specifications Parameters
- 3. Axis Specifications Parameters
- 4. Servo Parameters
- 5. Spindle Parameters
- 6. Multi-CPU Parameters
- 7. FL-net Parameters
- 8. DeviceNet Parameters
- 9. Machine Error Compensation Parameters
- 10. PLC Parameters
- 11. Macro List
- 12. Position Switches
- 13. PLC Axis Indexing Parameters
- III PLC Devices
- Revision History
- Back cover

II Parameters
Spindle Parameters
II - 119
【#13220】 SP220
Not used. Set to "0".
【#13221】 SP221
Not used. Set to "0".
【#13222】 SP222
Not used. Set to "0".
【#13223】 SP223
Not used. Set to "0".
【#13224】 SP224
Not used. Set to "0".
【#13225】 SP225 SFNC5 Spindle function 5
Select the spindle functions.
Functions are allocated to each bit.
Set this in hexadecimal format.
bit F-C : ovsn Overshooting compensation type 3 non-sensitive band
Set the non-sensitive band of the overshooting compensation type 3 in increments of 2°/
1000.
In the feed forward control, set the non-sensitive band for the model position droop and
ignore the model overshooting. Set to "2°/1000" as a standard.
bit B-9 :
Not used. Set to "0".
bit 8 : mken Coil switch allowance in deceleration control
This enables a coil changeover while decelerating after an emergency stop for a spindle
motor with coil changeover specification. A coil changeover may enable an excessive load
inertia to stop within the maximum delay time.
0: Normal (Disable) 1: Enable
bit 7-6 : thno
Select the thermistor characteristics.
When SP225/bit3=0 (N type) is selected
bit7,6=
00: For Mitsubishi spindle motor
01: Setting prohibited
10: Setting prohibited
11: Setting prohibited
When SP225/bit3=1 (P type) is selected
bit7,6=
00: KTY84-130 (Manufactured by Philips)
01: Setting prohibited
10: Setting prohibited
11: Setting prohibited
bit 5 : ddir Proximity switch signal enable edge
0: Falling edge 1: Rising edge
bit 4 : dcd DC excitation mode
0: Normal 1: Start
bit 3 : thtyp
Select the thermistor type.
0: Type N thermistor (Mitsubishi standard) 1: Type P thermistor
bit 2 : mohn Thermistor temperature detection
0: Normal 1: Disable (Except for TS5690/5691)
bit 1-0 :
Not used. Set to "0".
ddir
ovsn
dcd
mohn
mken
thtyp
thno