Specifications
Table Of Contents
- Front cover
- Trademarks
- Contents
- Remedy and measure after a report of error
- I Alarms
- 1. Operation Errors (M)
- 2. Stop Codes (T)
- 3. Servo/Spindle Alarms (S)
- 4. MCP Alarms (Y)
- 5. Safety Observation Alarms (Y)
- 6. System Alarms (Z)
- 7. Absolute Position Detection System Alarms (Z7*)
- 8. Emergency Stop Alarms (EMG)
- 9. Auxiliary Axis Operation Errors (M)
- 10. CNCCPU-side Safety Sequence Alarm(U)
- 11. Multi CPU Errors (A)
- 12. Network Errors (L)
- 13. Program Errors (P)
- II Parameters
- 1. Machining Parameters
- 2. Base Specifications Parameters
- 3. Axis Specifications Parameters
- 4. Servo Parameters
- 5. Spindle Parameters
- 6. Multi-CPU Parameters
- 7. FL-net Parameters
- 8. DeviceNet Parameters
- 9. Machine Error Compensation Parameters
- 10. PLC Parameters
- 11. Macro List
- 12. Position Switches
- 13. PLC Axis Indexing Parameters
- III PLC Devices
- Revision History
- Back cover

II Parameters
Spindle Parameters
II - 89
【#3050】 sprlv Spindle synchronization rotation speed attainment level
Set the level of speed difference between the basic and synchronous spindles during
spindle synchronization control. Setting of the synchronous spindle side is enabled. When
the difference becomes below the setting level, the spindle speed synchronization complete
signal will turn ON.
---Setting range---
0 to 4095 (pulse) (1 pulse = 0.088°)
【#3051】 spplv Spindle phase synchronization attainment level
Set the level of phase difference between the basic and synchronous spindles during
spindle synchronization. Setting of the synchronous spindle side is validated. When the
difference becomes below the setting level, the spindle phase synchronization complete
signal will go ON.
---Setting range---
0 to 4095 (pulse) (1 pulse = 0.088°)
【#3052】 spplr Spindle synchronization relative polarity
Set the spindle motor and spindle's relative polarity.
0: Positive polarity
(Spindle CW rotation at motor CW rotation)
1: Negative polarity
(Spindle CCW rotation at motor CW rotation)
【#3053】 sppst Spindle encoder Z -phase position
Set the deviation amount from the spindle's basic point to the spindle encoder's Z phase.
Obtain the deviation amount, considering a clockwise direction as positive when viewed
from the spindle's front side.
---Setting range---
0 to 359999 (1/1000°)
【#3054】 sptc1 Spindle synchronization multi-step acceleration/deceleration changeover
speed 1
Set the speed which switches from 1st step to 2nd step in spindle synchronization multi-
step acceleration/deceleration control. Set the same value for the reference axis and
synchronous axis.
Set the value of limit rotation speed (slimit) or higher not to carry out a step shift.
---Setting range---
0 to 99999 (r/min)
【#3055】 sptc2 Spindle synchronization multi-step acceleration/deceleration changeover
speed 2
Set the speed which switches from 2nd step to 3rd step in spindle synchronization multi-
step acceleration/deceleration control. Set the same value for the reference axis and
synchronous axis.
Set the value of limit rotation speed (slimit) or higher not to carry out a step shift.
---Setting range---
0 to 99999 (r/min)
【#3056】 sptc3 Spindle synchronization multi-step acceleration/deceleration changeover
speed 3
Set the speed which switches from 3rd step to 4th step in spindle synchronization multi-step
acceleration/deceleration control. Set the same value for the reference axis and
synchronous axis.
Set the value of limit rotation speed (slimit) or higher not to carry out a step shift.
---Setting range---
0 to 99999 (r/min)
【#3057】 sptc4 Spindle synchronization multi-step acceleration/deceleration changeover
speed 4
Set the speed which switches from 4th step to 5th step in spindle synchronization multi-step
acceleration/deceleration control. Set the same value for the reference axis and
synchronous axis.
Set the value of limit rotation speed (slimit) or higher not to carry out a step shift.
---Setting range---
0 to 99999 (r/min)
【#3058】 sptc5 Spindle synchronization multi-step acceleration/deceleration changeover
speed 5
Set the speed which switches from 5th step to 6th step in spindle synchronization multi-step
acceleration/deceleration control. Set the same value for the reference axis and
synchronous axis.
Set the value of limit rotation speed (slimit) or higher not to carry out a step shift.
---Setting range---
0 to 99999 (r/min)