Specifications
Table Of Contents
- Front cover
- Trademarks
- Contents
- Remedy and measure after a report of error
- I Alarms
- 1. Operation Errors (M)
- 2. Stop Codes (T)
- 3. Servo/Spindle Alarms (S)
- 4. MCP Alarms (Y)
- 5. Safety Observation Alarms (Y)
- 6. System Alarms (Z)
- 7. Absolute Position Detection System Alarms (Z7*)
- 8. Emergency Stop Alarms (EMG)
- 9. Auxiliary Axis Operation Errors (M)
- 10. CNCCPU-side Safety Sequence Alarm(U)
- 11. Multi CPU Errors (A)
- 12. Network Errors (L)
- 13. Program Errors (P)
- II Parameters
- 1. Machining Parameters
- 2. Base Specifications Parameters
- 3. Axis Specifications Parameters
- 4. Servo Parameters
- 5. Spindle Parameters
- 6. Multi-CPU Parameters
- 7. FL-net Parameters
- 8. DeviceNet Parameters
- 9. Machine Error Compensation Parameters
- 10. PLC Parameters
- 11. Macro List
- 12. Position Switches
- 13. PLC Axis Indexing Parameters
- III PLC Devices
- Revision History
- Back cover

II Parameters
Spindle Parameters
II - 88
【#3041】 tapt21 Synchronous tapping 2nd step acceleration/deceleration time constant
(Gear: 00)
Set the time constant for synchronous tapping 2nd step linear acceleration/deceleration
control when gear 00 is selected.
---Setting range---
1 to 5000 (ms)
【#3042】 tapt22 Synchronous tapping 2nd step acceleration/deceleration time constant 2
(Gear: 01)
Set the time constant for synchronous tapping 2nd step linear acceleration/deceleration
control when gear 01 is selected.
---Setting range---
1 to 5000 (ms)
【#3043】 tapt23 Synchronous tapping 2nd step acceleration/deceleration time constant
(Gear: 10)
Set the time constant for synchronous tapping 2nd step linear acceleration/deceleration
control when gear 10 is selected.
---Setting range---
1 to 5000 (ms)
【#3044】 tapt24 Synchronous tapping 2nd step acceleration/deceleration time constant
(Gear: 11)
Set the time constant for synchronous tapping 2nd step linear acceleration/deceleration
control when gear 11 is selected.
---Setting range---
1 to 5000 (ms)
【#3045】 tapt31 Synchronous tapping 3rd step acceleration/deceleration time constant
(Gear: 00)
Set the time constant for synchronous tapping 3rd step linear acceleration/deceleration
control when gear 00 is selected.
The inclination of linear acceleration/deceleration control for 3rd step is determined by the
ratio of slimit1(#3001) to tapt31(#3045).
---Setting range---
1 to 5000 (ms)
【#3046】 tapt32 Synchronous tapping 3rd step acceleration/deceleration time constant
(Gear: 01)
Set the time constant for synchronous tapping 3rd step linear acceleration/deceleration
control when gear 01 is selected.
The inclination of linear acceleration/deceleration control for 3rd step is determined by the
ratio of slimit2(#3002) to tapt32(#3046).
---Setting range---
1 to 5000 (ms)
【#3047】 tapt33 Synchronous tapping 3rd step acceleration/deceleration time constant
(Gear: 10)
Set the time constant for synchronous tapping 3rd step linear acceleration/deceleration
control when gear 10 is selected.
The inclination of linear acceleration/deceleration control for 3rd step is determined by the
ratio of slimit3(#3003) to tapt33(#3047).
---Setting range---
1 to 5000 (ms)
【#3048】 tapt34 Synchronous tapping 3rd step acceleration/deceleration time constant
(Gear: 11)
Set the time constant for synchronous tapping 3rd step linear acceleration/deceleration
control when gear 11 is selected.
The inclination of linear acceleration/deceleration control for 3rd step is determined by the
ratio of slimit4(#3004) to tapt34(#3048).
---Setting range---
1 to 5000 (ms)
【#3049】 spt Spindle synchronization acceleration/deceleration time constant
Set the acceleration/deceleration time constant under spindle synchronization control.
The inclination of acceleration/deceleration control is determined by the ratio to limit rotation
speed (slimit). Set the same value for the reference axis and synchronous axis.
The time constant for 2nd step or subsequent steps is the magnification setting on the basis
of this setting value.
---Setting range---
0 to 9999 (ms)