Specifications

Table Of Contents
II Parameters
Servo Parameters
II - 69
#2236(PR) SV036 PTYP Power supply type/ Regenerative resistor type
MDS-D2/DH2 Series: Power supply type
When connecting a power supply unit, set a code for each power supply unit.
bit F-C : amp
Set the power backup function to be used.
No function used : 0
Deceleration and stop function at power failure : 8
bit B-8 : rtyp
Not used. Set to "0".
bit 7-0 : ptyp External emergency stop setting
When the emergency stop input signal of the power supply unit is "disabled"
Power supply unit is not connected : 00
MDS-D2-CV-37 / MDS-DH2-CV-37 : 04
MDS-D2-CV-75 / MDS-DH2-CV-75 : 08
MDS-D2-CV-110 / MDS-DH2-CV-110 : 11
MDS-D2-CV-185 / MDS-DH2-CV-185 : 19
MDS-D2-CV-300 / MDS-DH2-CV-300 : 30
MDS-D2-CV-370 / MDS-DH2-CV-370 : 37
MDS-D2-CV-450 / MDS-DH2-CV-450 : 45
MDS-D2-CV-550 / MDS-DH2-CV-550 : 55
MDS-DH2-CV-750 : 75
When the emergency stop input signal of the power supply unit is "enabled"
(Note) Set the power supply rotary switch to "4".
Power supply unit is not connected : 00
MDS-D2-CV-37 / MDS-DH2-CV-37 : 44
MDS-D2-CV-75 / MDS-DH2-CV-75 : 48
MDS-D2-CV-110 / MDS-DH2-CV-110 : 51
MDS-D2-CV-185 / MDS-DH2-CV-185 : 59
MDS-D2-CV-300 / MDS-DH2-CV-300 : 70
MDS-D2-CV-370 / MDS-DH2-CV-370 : 77
MDS-D2-CV-450 / MDS-DH2-CV-450 : 85
MDS-D2-CV-550 / MDS-DH2-CV-550 : 95
MDS-DH2-CV-750 : B5
MDS-DM2-SPV Series
Not used. Set to "0000".
External emergency stop power supply type is set by spindle parameter (SP032).
MDS-DJ-V1/V2 Series: Regenerative resistor type
Set the regenerative resistor type.
bit F-8 : amp(bit F-C) / rtyp(bit B-8)
Resistor built-in drive unit : 10
Setting prohibited : 11
MR-RB032 : 12
MR-RB12 or GZG200W39OHMK : 13
MR-RB32 or GZG200W120OHMK 3 units connected in parallel : 14
MR-RB30 or GZG200W39OHMK 3 units connected in parallel : 15
MR-RB50 or GZG300W39OHMK 3 units connected in parallel : 16
MR-RB31 or GZG200W20OHMK 3 units connected in parallel : 17
MR-RB51 or GZG300W20OHMK 3 units connected in parallel : 18
Setting prohibited : 19-1F
Setting prohibited : 20-23
FCUA-RB22 : 24
FCUA-RB37 : 25
FCUA-RB55 : 26
FCUA-RB75/2 : 27
Setting prohibited : 28
R-UNIT2 : 29
Setting prohibited : 2A-2C
FCUA-RB75/2 2 units connected in parallel : 2D
FCUA-RB55 2 units connected in parallel : 2E
Setting prohibited : 2F
bit 7-4 : emgx External emergency stop function
Set the external emergency stop function.
0: Disable 4: Enable
bit 3-0 :
Not used. Set to "0".
ptyp
rtyp
amp
emgx
rtyp
amp
0000