Specifications
Table Of Contents
- Front cover
- Trademarks
- Contents
- Remedy and measure after a report of error
- I Alarms
- 1. Operation Errors (M)
- 2. Stop Codes (T)
- 3. Servo/Spindle Alarms (S)
- 4. MCP Alarms (Y)
- 5. Safety Observation Alarms (Y)
- 6. System Alarms (Z)
- 7. Absolute Position Detection System Alarms (Z7*)
- 8. Emergency Stop Alarms (EMG)
- 9. Auxiliary Axis Operation Errors (M)
- 10. CNCCPU-side Safety Sequence Alarm(U)
- 11. Multi CPU Errors (A)
- 12. Network Errors (L)
- 13. Program Errors (P)
- II Parameters
- 1. Machining Parameters
- 2. Base Specifications Parameters
- 3. Axis Specifications Parameters
- 4. Servo Parameters
- 5. Spindle Parameters
- 6. Multi-CPU Parameters
- 7. FL-net Parameters
- 8. DeviceNet Parameters
- 9. Machine Error Compensation Parameters
- 10. PLC Parameters
- 11. Macro List
- 12. Position Switches
- 13. PLC Axis Indexing Parameters
- III PLC Devices
- Revision History
- Back cover

II Parameters
Axis Specifications Parameters
II - 50
【#2029】 grspc Grid interval
Set a detector's grid interval.
Normally, set a value equal to the ball screw pitch. However, if the detector grid interval is
different from the screw pitch because a linear scale etc. is used, set the detector's grid
interval.
Use its divisors, if you wish to reduce the grid interval.
You can set the minimum setting increment to be 0.001mm, by using a negative value.
Example) Setting value
1 -> 1.000 mm (°)
-1 -> 0.001 mm (°)
Even when the specification is in sub-micrometric system, 0.001 mm is the minimum setting
increment.
---Setting range---
-32767 to 999(mm)
【#2030(PR)】 dir (-) Reference position direction (-)
Select which side of the near-point dog the reference position is established.
0: Positive direction
1: Negative direction
Directions in which reference position is established as viewed from the near-point dog
【#2031】 noref Axis without reference position
Select whether the reference position is provided for the axis.
0: Reference position is provided. (Normal controlled axis)
1: No reference position is provided.
When "1" is set, reference position return is not required before automatic operation starts.
【#2032】 nochk Whether reference position return is completed not checked
Select whether to check the reference position return completion.
0: Check the reference position return completion.
1: Not check the reference position return completion.
When "1" is set, the absolute and incremental commands can be executed even if dog type
(or Z phase pulse system) reference position return is not completed.
Note that this setting is available for a rotary axis only.
【#2037】 G53ofs Reference position #1
Set the position of the first reference position from the zero point of the basic machine
coordinate.
---Setting range---
-99999.999 to 99999.999 (mm)
Grid
+ direction
+ direction
- direction
Near-point dog
Near-point dog
Reference position
Reference position
Grid
- direction
Reference position #3
(#2039 #3_rfp)
Basic machine coordinate
Reference position #4
(#2040 #4_rfp)
Reference position #2
(#2038 #2_rfp)
Reference position #1
(#2037 G53ofs)