Specifications

Table Of Contents
II Parameters
Axis Specifications Parameters
II - 46
#2005 G0t1 G0 time constant(primary delay) / Second-step time constant for soft
acceleration/deceleration
Set a primary-delay time constant for rapid traverse acceleration and deceleration.
The time constant will be enabled when R1 (rapid traverse feed with primary delay) or R3
(exponential acceleration and linear deceleration) is selected in "#2003 smgst Acceleration
and deceleration modes".
When the soft acceleration/deceleration is selected, the second-step time constant will be
used.
<Rapid traverse feed with primary delay>
<Rapid traverse feed with exponential acceleration and linear deceleration>
<Soft acceleration/deceleration>
---Setting range---
1 to 5000 (ms)
#2006 G0t2
Not used. Set to "0".
#2007 G1tL G1 time constant (linear)
Set a linear control time constant for cutting acceleration and deceleration.
The time constant will be enabled when LC (cutting feed with linear acceleration/
deceleration) or F (soft acceleration/deceleration) is selected in "#2003 smgst Acceleration
or deceleration modes".
---Setting range---
1 to 4000 (ms)
G0t1
G0t1
Time
Speed
G0t1
2 x G0t1
Time
Speed
G0tL
G0tL
G0t1
G0t1
G0t1
G0t1
Time
Speed
G1tL G1tL
Time
Speed