II Parameters
Base Specifications Parameters
II - 41
#21104 add04
bit0: Search mode hold (word edit)
Set hold/non-hold of search mode.
0 : When a search is executed, go back to the 1st menu. (conventional)
1 : Hold the search mode even if a search is executed.
bit2: Search menu ON (screen edit)
Switch operation methods for data search.
0 : Execute string search downward. (conventional)
1 : Switch to search menu for the word/string search to execute upward/downward
search.
bit3: Default insert ON (screen edit)
Switch the mode between insert/write.
0 : Turn ON the overwrite mode when the screen is switched. (conventional)
1 : Turn ON the insert mode when the screen is switched, and it is held until the next
screen switching.
bit4: Switching the number of lines to feed (screen edit)
Switch the page feeding for the edit programs.
0 : Feed 11 lines.(conventional)
1 : Feed 12 lines in screen units.
#21105 add05
bit0: Program in-position type 2
Select the operation type of programmable in-position check.
0: When "#1193 inpos" is "1" or "3", ",I" command is enabled. The maximum difference
between ",I" command value and the parameter setting value is enabled.
1: Regardless of "#1193 inpos" setting, ",I" command is enabled. Only ",I" command
value is enabled.
bit1: Macro single speeding up
Select a state of continuous operation when "#8101 macro single" is enabled.
0: Disable
1: Enable
bit2: Conventional Emergency stop canceling method
Select the method for emergency stop cancel process.
0: Check the hot line gate OFF signal and cancel the emergency stop
1: Conventional method (without checking the gate OFF signal)
* Normally, "0" is set. Setting "1" is to avoid a failure in the emergency stop cancel.
#21113 add13
bit0: DeviceNet error monitor
Select whether to enable the DeviceNet error monitoring.
0 : Disable
1 : Enable
#21125(PR) SSU_num Number of dual signal modules
Set the number of dual signal modules to install.
Setting to "0" means that the dual-signal comparison is not carried out.
---Setting range---
0 to 3
#21126 to 21141(PR) SODR_1 to SODR_16 Speed monitor input device door 1 to 16
Set the device Nos. to which the door sensor signal is input to inform the open/close states
of the doors 1 to 16 during speed monitoring.
Setting to "0" means that the door is always open.
Therefore, "X0" cannot be used as the input device of door signals.
(Note)These settings will be ignored when #21163(InvalidDoorSgnl) is set to "1".
---Setting range---
0000 to 01FF (hexadecimal)
#21142(PR) SSU_delay Dual-signal comparison tolerance time
Set the time in which mismatches of input/output signals to/from PLC and NC in the dual
signal module are allowed.
When set to "0", the signal comparison tolerance time is 100ms.
---Setting range---
0 to 50(100ms)
#21143 to 21145(PR) SSU_Dev1 to SSU_Dev3 Dual signal module device
Set the head device Nos. to which the dual signal modules, station No. 0 to 2, are installed.
This I/O assignments need to correspond to those in GX Works2 / GX Developer.
The same device No. cannot be shared among different modules.
---Setting range---
0000 to 01FF (hexadecimal)