Specifications
Table Of Contents
- Front cover
- Trademarks
- Contents
- Remedy and measure after a report of error
- I Alarms
- 1. Operation Errors (M)
- 2. Stop Codes (T)
- 3. Servo/Spindle Alarms (S)
- 4. MCP Alarms (Y)
- 5. Safety Observation Alarms (Y)
- 6. System Alarms (Z)
- 7. Absolute Position Detection System Alarms (Z7*)
- 8. Emergency Stop Alarms (EMG)
- 9. Auxiliary Axis Operation Errors (M)
- 10. CNCCPU-side Safety Sequence Alarm(U)
- 11. Multi CPU Errors (A)
- 12. Network Errors (L)
- 13. Program Errors (P)
- II Parameters
- 1. Machining Parameters
- 2. Base Specifications Parameters
- 3. Axis Specifications Parameters
- 4. Servo Parameters
- 5. Spindle Parameters
- 6. Multi-CPU Parameters
- 7. FL-net Parameters
- 8. DeviceNet Parameters
- 9. Machine Error Compensation Parameters
- 10. PLC Parameters
- 11. Macro List
- 12. Position Switches
- 13. PLC Axis Indexing Parameters
- III PLC Devices
- Revision History
- Back cover

II Parameters
Base Specifications Parameters
II - 40
【#21052】 plcskip2 G31.2 skip condition
Designate the PLC skip signal in multi-step skip G31.2.
The PLC skip signal 1 to 32 is corresponded to bit0 to 31.
---Setting range---
00000000 to FFFFFFFF(HEX)
【#21053】 plcskip3 G31.3 skip condition
Designate the PLC skip signal in multi-step skip G31.3.
The PLC skip signal 1 to 32 is corresponded to bit0 to 31.
---Setting range---
00000000 to FFFFFFFF(HEX)
【#21101】 add01
bit0: FPLC axis rapid traverse mode acceleration/deceleration type
Select the acceleration/ deceleration type in PLC axis's rapid traverse mode.
0 : Select constant time-constant acceleration/deceleration
1 : Select constant inclination acceleration/deceleration
(Note) This parameter cannot be used when the peripheral axis (MC1K I/F) is used.
bit1: FPLC axis cutting feed mode acceleration/ deceleration type /Peripheral axis (MC1K
I/F) acceleration/ deceleration type
Select the acceleration/ deceleration type in PLC axis's cutting feed mode.
0 : Select constant time-constant acceleration/deceleration
1 : Select constant inclination acceleration/deceleration
(Note) Select the peripheral axis's (MC1K I/F) acceleration/deceleration type when the
peripheral axis is used.
bit2: FCircular command block overlap enabled
Select whether to enable the block overlap at the circular command.
0 : Disable
1 : Enable
bit3: FG31 automatic acceleration/ deceleration
Select whether to enable dry run, override and automatic acceleration/ deceleration for the
G31 (skip) command.
0 : Disable
1 : Enable
bit4
Reserved for system.
bit5
Reserved for system.
bit6
Reserved for system.
【#21102】 add02
bit1
Reserved for system.
bit2
Reserved for system.
【#21103】 add03
bit0
Reserved for system.
bit1
Reserved for system.