Specifications

Table Of Contents
II Parameters
Base Specifications Parameters
II - 40
#21052 plcskip2 G31.2 skip condition
Designate the PLC skip signal in multi-step skip G31.2.
The PLC skip signal 1 to 32 is corresponded to bit0 to 31.
---Setting range---
00000000 to FFFFFFFF(HEX)
#21053 plcskip3 G31.3 skip condition
Designate the PLC skip signal in multi-step skip G31.3.
The PLC skip signal 1 to 32 is corresponded to bit0 to 31.
---Setting range---
00000000 to FFFFFFFF(HEX)
#21101 add01
bit0: FPLC axis rapid traverse mode acceleration/deceleration type
Select the acceleration/ deceleration type in PLC axis's rapid traverse mode.
0 : Select constant time-constant acceleration/deceleration
1 : Select constant inclination acceleration/deceleration
(Note) This parameter cannot be used when the peripheral axis (MC1K I/F) is used.
bit1: FPLC axis cutting feed mode acceleration/ deceleration type /Peripheral axis (MC1K
I/F) acceleration/ deceleration type
Select the acceleration/ deceleration type in PLC axis's cutting feed mode.
0 : Select constant time-constant acceleration/deceleration
1 : Select constant inclination acceleration/deceleration
(Note) Select the peripheral axis's (MC1K I/F) acceleration/deceleration type when the
peripheral axis is used.
bit2: FCircular command block overlap enabled
Select whether to enable the block overlap at the circular command.
0 : Disable
1 : Enable
bit3: FG31 automatic acceleration/ deceleration
Select whether to enable dry run, override and automatic acceleration/ deceleration for the
G31 (skip) command.
0 : Disable
1 : Enable
bit4
Reserved for system.
bit5
Reserved for system.
bit6
Reserved for system.
#21102 add02
bit1
Reserved for system.
bit2
Reserved for system.
#21103 add03
bit0
Reserved for system.
bit1
Reserved for system.