Specifications
Table Of Contents
- Front cover
- Trademarks
- Contents
- Remedy and measure after a report of error
- I Alarms
- 1. Operation Errors (M)
- 2. Stop Codes (T)
- 3. Servo/Spindle Alarms (S)
- 4. MCP Alarms (Y)
- 5. Safety Observation Alarms (Y)
- 6. System Alarms (Z)
- 7. Absolute Position Detection System Alarms (Z7*)
- 8. Emergency Stop Alarms (EMG)
- 9. Auxiliary Axis Operation Errors (M)
- 10. CNCCPU-side Safety Sequence Alarm(U)
- 11. Multi CPU Errors (A)
- 12. Network Errors (L)
- 13. Program Errors (P)
- II Parameters
- 1. Machining Parameters
- 2. Base Specifications Parameters
- 3. Axis Specifications Parameters
- 4. Servo Parameters
- 5. Spindle Parameters
- 6. Multi-CPU Parameters
- 7. FL-net Parameters
- 8. DeviceNet Parameters
- 9. Machine Error Compensation Parameters
- 10. PLC Parameters
- 11. Macro List
- 12. Position Switches
- 13. PLC Axis Indexing Parameters
- III PLC Devices
- Revision History
- Back cover

II Parameters
Base Specifications Parameters
II - 39
【#21037】 FTP Host address FTP server IP address
Set the FTP server IP address.
Separate the each element with "." (period).
---Setting range---
Setting must be done in accordance with the network code of the connecting
environment.
【#21038】 FTP User name FTP server login name
Set the FTP server login name.
---Setting range---
15 or less alphabets, numbers, and symbols.
Alphabets in capital letters only.
【#21039】 FTP PASSWORD FTP server login password
Set the FTP server login password.
---Setting range---
15 or less alphabets, numbers, and symbols.
Alphabets in capital letters only.
【#21040】 FTP Directory Downloaded file's pass
Set the pass of the file to be downloaded.
Use (*) for colons (:) which separate drive names. * will be recognaized as the end of the
drive name.
Input slash (/) instead of (\) to mark off the directory, even if the server is Windows.
---Setting range---
20 or less characters.
Alphabets in capital letters only.
【#21041】 FTP File name Downloaded file's name
Set the name of the file to be downloaded.
---Setting range---
20 or less characters.
Alphabets in capital letters only.
【#21042】 FTP Retry Num retry
Set the number of times to retry when a connection error occurs.
---Setting range---
0 to 999 (times)
【#21043】 FTP Timeout Connection time out
Set the timeout time when connecting.
---Setting range---
0 to 99 (s)
【#21048】 mmacpro Tool builders macro password
Resister and certify a password for editing machine builder macro programs and other
operations.
- When the password has not been set yet, less than eight letters of arbitrary alphabets in
capitals and numbers except "0" can be set.
- When the password is already registered (displaying ****), enter this password to cancel
protection and the password will be displayed. Entering a password that is not registered
causes "E01 Setting error".
---Setting range---
Up to eight letters of alphabets in capitals and numbers. ("0" is not accepted.)
【#21049】 SPname
Select the spindle No. to be selected in G43.1 modal for each part system.
0 : 1st spindle
1 : 1st spindle
2 : 2nd spindle
3 : 3rd spindle
4 : 4th spindle
5 : 5th spindle
6 : 6th spindle
7 : 7th spindle
【#21050】 plcdwlskp G04 skip condition
Set the PLC skip signal for suspending the G04 (dwell) command.
The PLC skip signal 1 to 32 is corresponded to bit0 to 31.
---Setting range---
00000000 to FFFFFFFF(HEX)
【#21051】 plcskip1 G31.1 skip condition
Designate the PLC skip signal in multi-step skip G31.1.
The PLC skip signal 1 to 32 is corresponded to bit0 to 31.
---Setting range---
00000000 to FFFFFFFF(HEX)










