Specifications

Table Of Contents
II Parameters
Base Specifications Parameters
II - 39
#21037 FTP Host address FTP server IP address
Set the FTP server IP address.
Separate the each element with "." (period).
---Setting range---
Setting must be done in accordance with the network code of the connecting
environment.
#21038 FTP User name FTP server login name
Set the FTP server login name.
---Setting range---
15 or less alphabets, numbers, and symbols.
Alphabets in capital letters only.
#21039 FTP PASSWORD FTP server login password
Set the FTP server login password.
---Setting range---
15 or less alphabets, numbers, and symbols.
Alphabets in capital letters only.
#21040 FTP Directory Downloaded file's pass
Set the pass of the file to be downloaded.
Use (*) for colons (:) which separate drive names. * will be recognaized as the end of the
drive name.
Input slash (/) instead of (\) to mark off the directory, even if the server is Windows.
---Setting range---
20 or less characters.
Alphabets in capital letters only.
#21041 FTP File name Downloaded file's name
Set the name of the file to be downloaded.
---Setting range---
20 or less characters.
Alphabets in capital letters only.
#21042 FTP Retry Num retry
Set the number of times to retry when a connection error occurs.
---Setting range---
0 to 999 (times)
#21043 FTP Timeout Connection time out
Set the timeout time when connecting.
---Setting range---
0 to 99 (s)
#21048 mmacpro Tool builders macro password
Resister and certify a password for editing machine builder macro programs and other
operations.
- When the password has not been set yet, less than eight letters of arbitrary alphabets in
capitals and numbers except "0" can be set.
- When the password is already registered (displaying ****), enter this password to cancel
protection and the password will be displayed. Entering a password that is not registered
causes "E01 Setting error".
---Setting range---
Up to eight letters of alphabets in capitals and numbers. ("0" is not accepted.)
#21049 SPname
Select the spindle No. to be selected in G43.1 modal for each part system.
0 : 1st spindle
1 : 1st spindle
2 : 2nd spindle
3 : 3rd spindle
4 : 4th spindle
5 : 5th spindle
6 : 6th spindle
7 : 7th spindle
#21050 plcdwlskp G04 skip condition
Set the PLC skip signal for suspending the G04 (dwell) command.
The PLC skip signal 1 to 32 is corresponded to bit0 to 31.
---Setting range---
00000000 to FFFFFFFF(HEX)
#21051 plcskip1 G31.1 skip condition
Designate the PLC skip signal in multi-step skip G31.1.
The PLC skip signal 1 to 32 is corresponded to bit0 to 31.
---Setting range---
00000000 to FFFFFFFF(HEX)