Specifications

Table Of Contents
II Parameters
Base Specifications Parameters
II - 38
#12021(PR) r_lim- Actual axis movable range (-)
In the hypothetic axis mode, set a movable range of the actual linear axis in negative
direction in the hypothetic plane with a distance from the machine zero point.
---Setting range---
0 to 99999.999 (mm)
#21025 SmpDelay
Set a sampling time after an alarm occurs.
---Setting range---
0 to 3000 (ms)
#21028 ed_mess
Set an edit type.
0 : Display messages with state
1 : Display operation messages
#21029 NCname
Set this to display the NC unit name on the CE terminal screen.
---Setting range---
8 or less alphanumeric characters
#21030 AlmHold (h)
Set the time to delete sampling data automatically after an alarm occurs.
If "0" is set, the alarm will not be deleted automatically.
---Setting range---
0 to 9999 (h)
#21031 UnitMax
Set the number of control units to connect when setting and displaying several NC units with
one terminal using the multiple NC common display function. Up to 15 NC control units can
be connected.
As the default value is "0", the number of NC units to connect will be regarded as one
unless you set this parameter.
(The setting values "0" and "1" are handled in the same manner.)
---Setting range---
0 to 15 (Default value : 0)
#21032 UnitNum
Set the control unit's station No. when setting and displaying several NC units with one
terminal using the multiple NC common display function.
"0" is the first station No. and "14" is the last station No.
Make sure that the stations are not set in duplicate.
---Setting range---
0 to 14 (Default value: 0)
#21033 KeyCtrlLmt
Select the limit type of key operation right acquisition.
0: Enable the acquisition of key operation right from another display unit for all the
screens.
1: Disable the acquisition of key operation right while the program screen is opened.
2: Disable the acquisition of key operation right from another display unit for all the
screens.
#21034 ReMonDisp
Select the display limitation of the remote monitor tool.
0: Not limit the remote monitor tool displays.
1: Not send the display information to the remote monitor tool.
(Note) Avoid setting from the remote monitor tool.
The display will not appear from the time you set this parameter.
#21035 ComErrDly Communication alarm display delay
Displaying the error and storing the error in the alarm history will be delayed for the set time
duration when a communication error (Y02 System alarm 0051) occurs.
Set this parameter if a communication error occurs when turning OFF the power. If not (if
not using), set to "0".
---Setting range---
0 to 5000 (ms)
#21036 SrvAlmDly Servo alarm display delay
Displaying the error and storing the error in the alarm history will be delayed for the set time
duration when a servo/spindle alarm occurs.
Set this parameter if a servo/spindle alarm occurs when turning OFF the power. If not (or if
not using), set to "0".
---Setting range---
0 to 5000 (ms)