Specifications
Table Of Contents
- Front cover
- Trademarks
- Contents
- Remedy and measure after a report of error
- I Alarms
- 1. Operation Errors (M)
- 2. Stop Codes (T)
- 3. Servo/Spindle Alarms (S)
- 4. MCP Alarms (Y)
- 5. Safety Observation Alarms (Y)
- 6. System Alarms (Z)
- 7. Absolute Position Detection System Alarms (Z7*)
- 8. Emergency Stop Alarms (EMG)
- 9. Auxiliary Axis Operation Errors (M)
- 10. CNCCPU-side Safety Sequence Alarm(U)
- 11. Multi CPU Errors (A)
- 12. Network Errors (L)
- 13. Program Errors (P)
- II Parameters
- 1. Machining Parameters
- 2. Base Specifications Parameters
- 3. Axis Specifications Parameters
- 4. Servo Parameters
- 5. Spindle Parameters
- 6. Multi-CPU Parameters
- 7. FL-net Parameters
- 8. DeviceNet Parameters
- 9. Machine Error Compensation Parameters
- 10. PLC Parameters
- 11. Macro List
- 12. Position Switches
- 13. PLC Axis Indexing Parameters
- III PLC Devices
- Revision History
- Back cover

II Parameters
Base Specifications Parameters
II - 38
【#12021(PR)】 r_lim- Actual axis movable range (-)
In the hypothetic axis mode, set a movable range of the actual linear axis in negative
direction in the hypothetic plane with a distance from the machine zero point.
---Setting range---
0 to 99999.999 (mm)
【#21025】 SmpDelay
Set a sampling time after an alarm occurs.
---Setting range---
0 to 3000 (ms)
【#21028】 ed_mess
Set an edit type.
0 : Display messages with state
1 : Display operation messages
【#21029】 NCname
Set this to display the NC unit name on the CE terminal screen.
---Setting range---
8 or less alphanumeric characters
【#21030】 AlmHold (h)
Set the time to delete sampling data automatically after an alarm occurs.
If "0" is set, the alarm will not be deleted automatically.
---Setting range---
0 to 9999 (h)
【#21031】 UnitMax
Set the number of control units to connect when setting and displaying several NC units with
one terminal using the multiple NC common display function. Up to 15 NC control units can
be connected.
As the default value is "0", the number of NC units to connect will be regarded as one
unless you set this parameter.
(The setting values "0" and "1" are handled in the same manner.)
---Setting range---
0 to 15 (Default value : 0)
【#21032】 UnitNum
Set the control unit's station No. when setting and displaying several NC units with one
terminal using the multiple NC common display function.
"0" is the first station No. and "14" is the last station No.
Make sure that the stations are not set in duplicate.
---Setting range---
0 to 14 (Default value: 0)
【#21033】 KeyCtrlLmt
Select the limit type of key operation right acquisition.
0: Enable the acquisition of key operation right from another display unit for all the
screens.
1: Disable the acquisition of key operation right while the program screen is opened.
2: Disable the acquisition of key operation right from another display unit for all the
screens.
【#21034】 ReMonDisp
Select the display limitation of the remote monitor tool.
0: Not limit the remote monitor tool displays.
1: Not send the display information to the remote monitor tool.
(Note) Avoid setting from the remote monitor tool.
The display will not appear from the time you set this parameter.
【#21035】 ComErrDly Communication alarm display delay
Displaying the error and storing the error in the alarm history will be delayed for the set time
duration when a communication error (Y02 System alarm 0051) occurs.
Set this parameter if a communication error occurs when turning OFF the power. If not (if
not using), set to "0".
---Setting range---
0 to 5000 (ms)
【#21036】 SrvAlmDly Servo alarm display delay
Displaying the error and storing the error in the alarm history will be delayed for the set time
duration when a servo/spindle alarm occurs.
Set this parameter if a servo/spindle alarm occurs when turning OFF the power. If not (or if
not using), set to "0".
---Setting range---
0 to 5000 (ms)