Specifications
Table Of Contents
- Front cover
- Trademarks
- Contents
- Remedy and measure after a report of error
- I Alarms
- 1. Operation Errors (M)
- 2. Stop Codes (T)
- 3. Servo/Spindle Alarms (S)
- 4. MCP Alarms (Y)
- 5. Safety Observation Alarms (Y)
- 6. System Alarms (Z)
- 7. Absolute Position Detection System Alarms (Z7*)
- 8. Emergency Stop Alarms (EMG)
- 9. Auxiliary Axis Operation Errors (M)
- 10. CNCCPU-side Safety Sequence Alarm(U)
- 11. Multi CPU Errors (A)
- 12. Network Errors (L)
- 13. Program Errors (P)
- II Parameters
- 1. Machining Parameters
- 2. Base Specifications Parameters
- 3. Axis Specifications Parameters
- 4. Servo Parameters
- 5. Spindle Parameters
- 6. Multi-CPU Parameters
- 7. FL-net Parameters
- 8. DeviceNet Parameters
- 9. Machine Error Compensation Parameters
- 10. PLC Parameters
- 11. Macro List
- 12. Position Switches
- 13. PLC Axis Indexing Parameters
- III PLC Devices
- Revision History
- Back cover

II Parameters
Base Specifications Parameters
II - 36
【#1821】 Hcof_A Y-axis high acceleration coefficient β
---Setting range---
-99999999 to +99999999
【#1822】 Hcof_B Y-axis high acceleration coefficient α
---Setting range---
-99999999 to +99999999
【#1823】 Mcof_A Y-axis middle acceleration coefficient β
---Setting range---
-99999999 to +99999999
【#1824】 Mcof_B Y-axis middle acceleration coefficient α
---Setting range---
-99999999 to +99999999
【#1825】 Lcof_A Y-axis low acceleration coefficient β
---Setting range---
-99999999 to +99999999
【#1826】 Lcof_B Y-axis low acceleration coefficient α
---Setting range---
-99999999 to +99999999
【#1827】 mag_C Y-axis change magnification θ [%]
Set to "0" when no compensation or change is executed.
---Setting range---
-99999999 to +99999999
【#1926(PR)】 IP address IP address
Set the NC's IP address.
Set the NC IP address seen from an external source.
IP address will be "192.168.1.2" when NC is initialized.
【#1927(PR)】 Subnet mask Subnet mask
Set the subnet mask for the IP address.
【#1928(PR)】 Gateway address Gateway
Set the IP address for the gateway.
【#1929】 Port number Port No.
Set the HMI connection port No.
(Set the default value 64758 unless particularly required.)
---Setting range---
0 to 65535
【#1930(PR)】 Speed Auto/10M
Select the communication rate.
0 : Set the communication rate by automatically recognizing “10M” or “100M”.
1 : Fix the rate at "10M".
【#11033(PR)】 skipB_no_sens Unconnected sensor selection when skip is set to contact B
Select the contact of the sensor which you wish to set as unconnected, when the skip signal
is set to contact B.
Set "1" for the contact to be unconnected.
bit0: Skip input 1
bit1: Skip input 2
bit2: Skip input 3
bit3: Skip input 4
(Note 1)This parameter is enabled when "#1258 set30/bit0" is set to "1".
(Note 2)bit4 to bit7 are not used. Set to "0".
(Note 3)This parameter is independent of PLC skip.
---Setting range---
00000000 to 00001111 (Binary)
【#12015(PR)】 v_dist Hypothetical axis tool length
In the hypothetical linear axis control, set the length in the hypothetical plane from the
rotation center of the actual rotary axis to the tool center.
Setting "0" disables the hypothetical axis.
---Setting range---
0 to 99999.999 (mm)