Specifications
Table Of Contents
- Front cover
- Trademarks
- Contents
- Remedy and measure after a report of error
- I Alarms
- 1. Operation Errors (M)
- 2. Stop Codes (T)
- 3. Servo/Spindle Alarms (S)
- 4. MCP Alarms (Y)
- 5. Safety Observation Alarms (Y)
- 6. System Alarms (Z)
- 7. Absolute Position Detection System Alarms (Z7*)
- 8. Emergency Stop Alarms (EMG)
- 9. Auxiliary Axis Operation Errors (M)
- 10. CNCCPU-side Safety Sequence Alarm(U)
- 11. Multi CPU Errors (A)
- 12. Network Errors (L)
- 13. Program Errors (P)
- II Parameters
- 1. Machining Parameters
- 2. Base Specifications Parameters
- 3. Axis Specifications Parameters
- 4. Servo Parameters
- 5. Spindle Parameters
- 6. Multi-CPU Parameters
- 7. FL-net Parameters
- 8. DeviceNet Parameters
- 9. Machine Error Compensation Parameters
- 10. PLC Parameters
- 11. Macro List
- 12. Position Switches
- 13. PLC Axis Indexing Parameters
- III PLC Devices
- Revision History
- Back cover

II Parameters
Base Specifications Parameters
II - 35
【#1533】 millPax Pole coordinate linear axis name
Set the linear axis name used for pole coordinate interpolation.
---Setting range---
Axis name such as X, Y or Z
【#1535】 C_leng Minimum turning movement amount
Set the minimum turning movement amount of the normal line control axis at the block joint
during normal line control.
---Setting range---
0.000 to 99999.999 (mm)
【#1567】 mill_err Error between linear axis and rotary axis center
Set the error between the linear axis and the rotary axis center (the error being deviation
from the rotary axis center to the vertical direction of linear axis.)
Set the error amount by the radius value.
---Setting range---
-9999.999 to 9999.999 (mm)
【#1568】 SfiltG1 G01 soft acceleration/deceleration filter
Set the filter time constant for smoothly changing the acceleration rate for the cutting feed
acceleration/deceleration in pre-interpolation acceleration/deceleration.
---Setting range---
0 to 200 (ms)
【#1569】 SfiltG0 G00 soft acceleration/deceleration filter
Set the filter time constant for smoothly changing the acceleration rate for the rapid traverse
acceleration/deceleration in pre-interpolation acceleration/deceleration.
---Setting range---
0 to 200 (ms)
【#1570】 Sfilt2 Soft acceleration/deceleration filter 2
Set the filter time constant for smoothly changing the acceleration rate in pre-interpolation
acceleration/deceleration.
This will be disabled when "0" is set.
---Setting range---
0 to 50 (ms)
【#1801】 Hacc_c Arc radius clam acceleration
---Setting range---
-99999999 to +99999999
【#1802】 Macc_c Acceleration check at middle speed
---Setting range---
-99999999 to +99999999
【#1803】 Lacc_c Acceleration check at low speed
---Setting range---
-99999999 to +99999999
【#1811】 Hcof_A X-axis high acceleration coefficient β
---Setting range---
-99999999 to +99999999
【#1812】 Hcof_B X-axis high acceleration coefficient α
---Setting range---
-99999999 to +99999999
【#1813】 Mcof_A X-axis middle acceleration coefficient β
---Setting range---
-99999999 to +99999999
【#1814】 Mcof_B X-axis middle acceleration coefficient α
---Setting range---
-99999999 to +99999999
【#1815】 Lcof_A X-axis low acceleration coefficient β
---Setting range---
-99999999 to +99999999
【#1816】 Lcof_B X-axis low acceleration coefficient α
---Setting range---
-99999999 to +99999999
【#1817】 mag_C X-axis change magnification θ [%]
Set to "0" when no compensation or change is executed.
---Setting range---
-99999999 to +99999999