Specifications
Table Of Contents
- Front cover
- Trademarks
- Contents
- Remedy and measure after a report of error
- I Alarms
- 1. Operation Errors (M)
- 2. Stop Codes (T)
- 3. Servo/Spindle Alarms (S)
- 4. MCP Alarms (Y)
- 5. Safety Observation Alarms (Y)
- 6. System Alarms (Z)
- 7. Absolute Position Detection System Alarms (Z7*)
- 8. Emergency Stop Alarms (EMG)
- 9. Auxiliary Axis Operation Errors (M)
- 10. CNCCPU-side Safety Sequence Alarm(U)
- 11. Multi CPU Errors (A)
- 12. Network Errors (L)
- 13. Program Errors (P)
- II Parameters
- 1. Machining Parameters
- 2. Base Specifications Parameters
- 3. Axis Specifications Parameters
- 4. Servo Parameters
- 5. Spindle Parameters
- 6. Multi-CPU Parameters
- 7. FL-net Parameters
- 8. DeviceNet Parameters
- 9. Machine Error Compensation Parameters
- 10. PLC Parameters
- 11. Macro List
- 12. Position Switches
- 13. PLC Axis Indexing Parameters
- III PLC Devices
- Revision History
- Back cover

II Parameters
Base Specifications Parameters
II - 25
【#1223】 aux07
bit3: Synchronous tapping in-position check valid
0: Disable (Conventional method: execute same in-position check at the hole bottom/R
point)
1: Enable (Extension method: able to select the in-position check enable/disable at the
hole bottom/R point)
Related parameters:
#1223/bit4 Synchronous tapping hole bottom in-position check
bit4: Synchronous tapping hole bottom in-position check
Select enable/disable of Synchronous tapping hole bottom in-position check.
0: Disable
1: Enable
bit6: Synchronous tapping (,S) cancel
0: Retain a spindle speed (, S) when performing synchronous tapping retract.
1: Cancel a spindle speed (, S) by retract with G80.
bit7: Synchronous tapping method
Select a synchronous tapping method.
0: Enable multi-step acceleration/deceleration and rapid return synchronous tapping
1: Disable multi-step acceleration/deceleration and rapid return synchronous tapping
【#1224】 aux08
bit0: Data sampling valid
Set valid/invalid for the data sampling.
0: Setting of sampling parameter invalid
1: Setting of sampling parameter valid
【#1225】 aux09
bit5: Alarm history recording option of the safety observation warning
Select whether to record "Y21 Safety observation warning 0001" (Speed obsv signal:
Speed over) to the alarm history.
0: Record