Specifications
Table Of Contents
- Front cover
- Trademarks
- Contents
- Remedy and measure after a report of error
- I Alarms
- 1. Operation Errors (M)
- 2. Stop Codes (T)
- 3. Servo/Spindle Alarms (S)
- 4. MCP Alarms (Y)
- 5. Safety Observation Alarms (Y)
- 6. System Alarms (Z)
- 7. Absolute Position Detection System Alarms (Z7*)
- 8. Emergency Stop Alarms (EMG)
- 9. Auxiliary Axis Operation Errors (M)
- 10. CNCCPU-side Safety Sequence Alarm(U)
- 11. Multi CPU Errors (A)
- 12. Network Errors (L)
- 13. Program Errors (P)
- II Parameters
- 1. Machining Parameters
- 2. Base Specifications Parameters
- 3. Axis Specifications Parameters
- 4. Servo Parameters
- 5. Spindle Parameters
- 6. Multi-CPU Parameters
- 7. FL-net Parameters
- 8. DeviceNet Parameters
- 9. Machine Error Compensation Parameters
- 10. PLC Parameters
- 11. Macro List
- 12. Position Switches
- 13. PLC Axis Indexing Parameters
- III PLC Devices
- Revision History
- Back cover

II Parameters
Base Specifications Parameters
II - 24
【#1219】 aux03
bit1
Reserved for system.
bit3
Reserved for system.
bit7: Time constant setting changeover for soft acceleration/deceleration
0: Accelerating time is G0tL(G1tL).
When the G00 pre-interpolation acceleration/deceleration and the soft acceleration/
deceleration are used together, the inclination of soft acceleration/deceleration will
be steeper by setting a time to the soft acceleration/deceleration 2nd step time
constant (#2005 G0t1).
Consequently, the acceleration for G28/G30 will be larger than that for G00.
(1) Total accelerating time is "G0tL".
(2) The time for curve part is "G0t1".
(3) The time for linear part is obtained by "G0tL-(2 x G0t1)".
1: Accelerating time is obtained by G0tL+G0t1 (G1tL+G1t1).
When the G00 pre-interpolation acceleration/deceleration and the soft acceleration/
deceleration are used together, you can attain the G28/G30 acceleration that is
equal to G00, by setting the same value to G00 soft acceleration/deceleration filter
(#1569 SfiltG0) as well as to the soft acceleration/deceleration 2nd step time
constant (#2005 G0t1).
(1) Total accelerating time is obtained by "G0tL+G0t1".
(2) The time for curve part is "G0t1".
(3) The time for linear part is obtained by "G0tL-G0t1".
【#1220】 aux04
bit06: MDI part system interlock enabled
Select the part system in which the MDI setting is completed when pushing down the input
during editing MDI.
0: All the part systems
1: Only the part system being displayed
G0tl
G0tL㧙G0tl
G0tL
G0tl
㨠
㨠
S
p
eed
Acceleration
G0tL㧗G0t1
G0tL
G0t1
㨠
㨠
G0t1
Speed