Specifications

Table Of Contents
II Parameters
Base Specifications Parameters
II - 23
#1211 FHtyp Feed hold stop type
Select the type of the external signal used for feed hold.
0: Disable the external signal.
1: Enable the external signal (contact A)
2: Enable the external signal (contact B)
---Setting range---
0 to 2
#1212 FHno Feed hold external signal device
Set the device No. (X**) used to input the feed hold signal.
---Setting range---
000 to 2FF (hexadecimal)
#1216 extdcc External deceleration level
Set the upper limit value of the feedrate when the external deceleration signals are enabled.
This parameter is valid when "#1239 set11/bit6" is set to "0".
---Setting range---
1 to 1000000 (mm/min)
#1218 aux02
bit3: Parameter input/output format
Select the parameter input/output format.
0: Type I
1: Type II (related to "#1218 aux02/bit5")
bit4: External workpiece coordinate offset tool number selection
Select the R register that contains the tool number used for automatic calculation when
measuring the coordinate offset of an external workpiece.
0: Follow the setting of "#1130 set_t".
1: Use the tool number indicated by user PLC.
bit5: Parameter I/O II spindle specification address
Select the spindle specification address of parameter I/O type II.
0: C
1: T
This parameter is also applied to the spindle specification address for input and verification.
(Note) This parameter is valid only for parameter I/O type II (when "#1218 aux02/bit3" is set
to "1").
bit6: Set No. valid when program input
Select which program No. is applied when inputting programs in "#1 MAIN PROGRAM" on
Data I/O screen.
0: The No. in the input data
1: The No. set in the data setting area
bit7: Input by program overwrite
Select the operation when the program to be input in "#1 MAIN PROGRAM" on Data I/O
screen, has already been registered.
0: An operation error (E65) occurs.
1: Input by overwrite.