Specifications

Table Of Contents
II Parameters
Base Specifications Parameters
II - 18
#1180 skip3f G31.3 skip speed
Set the skip signal in multi-step skip G31.3.
---Setting range---
1 to 999999 (mm/min)
#1181 G96_ax Constant surface speed axis
Select the axis to be targeted for constant surface speed control.
0: Program setting will be disabled, and the axis will always be fixed to the 1st axis
1: 1st axis
2: 2nd axis
3: 3rd axis
:
8: 8th axis
However, when set to other than “0”, the priority will be on the program setting.
#1182 thr_F Thread cutting speed
Set the screw cut up speed when not using chamfering in the thread cutting cycle.
0: Cutting feed clamp feedrate
1 to 60000 mm/min: Setting feedrate
---Setting range---
0 to 60000 (mm/min)
#1183 clmp_M M code for clamp
Set the M code for C axis clamp in hole drilling cycle.
---Setting range---
0 to 99999999
#1184 clmp_D Dwelling time after outputting M code for unclamp
Set the dwell time after outputting the M code for C axis unclamp in hole drilling cycle.
---Setting range---
0.000 to 99999.999 (s)
#1185 spd_F1 F1 digit feedrate F1
Set the feedrate for the F command in the F 1-digit command ("#1079 F1digit" is set to "1").
Feedrate when F1 is issued (mm/min)
---Setting range---
1 to 1000000 (mm/min)
#1186 spd_F2 F1 digit feedrate F2
Set the feedrate for the F command in the F 1-digit command ("#1079 F1digit" is set to "1").
Feedrate when F2 is issued (mm/min)
---Setting range---
1 to 1000000 (mm/min)
#1187 spd_F3 F1 digit feedrate F3
Set the feedrate for the F command in the F 1-digit command ("#1079 F1digit" is set to "1").
Feedrate when F3 is issued (mm/min)
---Setting range---
1 to 1000000 (mm/min)
#1188 spd_F4 F1 digit feedrate F4
Set the feedrate for the F command in the F 1-digit command ("#1079 F1digit" is set to "1").
Feedrate when F4 is issued (mm/min)
---Setting range---
1 to 1000000 (mm/min)
#1189 spd_F5 F1 digit feedrate F5
Set the feedrate for the F command in the F 1-digit command ("#1079 F1digit" is set to "1").
Feedrate when F5 is issued (mm/min)
---Setting range---
1 to 1000000 (mm/min)
#1190(PR) s_xcnt Validate inclined axis control (for L system only)
Select whether to enable or disable inclined axis control.
0: Disable inclined axis control
1: Enable inclined axis control
#1191(PR) s_angl Inclination angle (for L system only)
Set the inclination angle α of the oblique coordinate X' axis from X axis on the orthogonal
coordinate system.
---Setting range---
-80.000 to 80.000 (°)
#1192(PR) s_zrmv Compensation at reference point return (for L system only)
Select whether to compensate for the Z axis motion during the X axis manual reference
position return under the inclined axis control.
0 : Compensate for Z axis
1 : Not compensate for Z axis