Specifications
Table Of Contents
- Front cover
- Trademarks
- Contents
- Remedy and measure after a report of error
- I Alarms
- 1. Operation Errors (M)
- 2. Stop Codes (T)
- 3. Servo/Spindle Alarms (S)
- 4. MCP Alarms (Y)
- 5. Safety Observation Alarms (Y)
- 6. System Alarms (Z)
- 7. Absolute Position Detection System Alarms (Z7*)
- 8. Emergency Stop Alarms (EMG)
- 9. Auxiliary Axis Operation Errors (M)
- 10. CNCCPU-side Safety Sequence Alarm(U)
- 11. Multi CPU Errors (A)
- 12. Network Errors (L)
- 13. Program Errors (P)
- II Parameters
- 1. Machining Parameters
- 2. Base Specifications Parameters
- 3. Axis Specifications Parameters
- 4. Servo Parameters
- 5. Spindle Parameters
- 6. Multi-CPU Parameters
- 7. FL-net Parameters
- 8. DeviceNet Parameters
- 9. Machine Error Compensation Parameters
- 10. PLC Parameters
- 11. Macro List
- 12. Position Switches
- 13. PLC Axis Indexing Parameters
- III PLC Devices
- Revision History
- Back cover

II Parameters
Base Specifications Parameters
II - 17
【#1169】 part system name Part system name
Set the name of each part system.
This must be set only when using multi-part system.
This name will be displayed on the screen only when the part systems must be identified.
Use a max. of four alphabetic characters or numerals.
---Setting range---
A max. of four alphabetic characters or numerals.
【#1170】 M2name Second miscellaneous code
Set this address code when using the 2nd miscellaneous command. Set an address with A,
B or C that is not used for "#1013 axname" or "#1014 incax".
---Setting range---
A, B, C
【#1171】 taprov Tap return override
Set the tap return override value for the synchronous tapping.
When "0" is set, it will be regarded as 100%.
---Setting range---
1 to 100 (%)
【#1172】 tapovr Tap return override
Set the override value when leaving the tap end point in the synchronous tapping cycle.
The setting range is 1 to 999, and the unit is %.
When a value less than 100 is set, it will be judged as 100%.
---Setting range---
1 to 999 (%)
【#1173】 dwlskp G04 skip condition
Set the skip signal for ending the G04 (dwell) command.
【#1174】 skip_F G31 skip speed
Set the feedrate when there is no F command in the program at G31 (skip) command.
---Setting range---
1 to 999999 (mm/min)
【#1175】 skip1 G31.1 skip condition
Designate the skip signal in multi-step skip G31.1.
The setting method is same as "#1173".
【#1176】 skip1f G31.2 skip speed
Set the skip feedrate in multi-step skip G31.1.
---Setting range---
1 to 999999 (mm/min)
【#1177】 skip2 G31.2 skip condition
Set the skip signal in multi-step skip G31.2.
The setting method is same as "#1173".
【#1178】 skip2f G31.2 skip speed
Set the skip signal in multi-step skip G31.2.
---Setting range---
1 to 999999 (mm/min)
【#1179】 skip3 G31.3 skip condition
Set the skip signal in multi-step skip G31.3
The setting method is same as "#1173".
SKIP3 SKIP2 SKIP1 SKIP0
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Skip when
Setting
Skip signals
signal is input.