#1147 smin_V Minimum spindle rotation speed clamp type
Specify the type of spindle min. rotation speed clamp value.
0: Rotation speed setting
1: Output voltage coefficient setting
Set “#3023 smini” according to this type setting.
#1148 I_G611 Initial high precision
Set the high accuracy control mode for the modal state when the power is turned ON.
0: G64 (cutting mode) at power ON
1: G61.1 (high-accuracy control mode) at power ON
#1149 cireft Arc deceleration speed change
Select whether to decelerate at the arc entrance or exit.
0: Not decelerate
1: Decelerate
#1150 Fldc0
Not used. Set to "0".
#1151 rstint Reset initial
Select whether to initialize (power ON state) the modals by resetting.
0: Not initialize modal state
1: Initialize modal state
#1152 I_G20 Initial command unit
Select inch or metric command mode at power-ON or resetting.
0 : Metric command (G21 command state)
1 : Inch command (G20 command state)
This selection is enabled at reset input.
Related parameter : "#1226 bit6" Set up and display unit selection
#1154(PR) pdoor
Not used. Set to "0".
#1155 DOOR_m Signal input device 1 for door interlock II
Set a fixed device No. (X device No.) to input the door interlock II signal.
Using this device can realize the same operation as the door open II signal input, without
passing through the PLC.
"000" can not be used as a fixed device No.
When not using the fixed device No, set this to "100".
(Note) When you set a device No. with this parameter, make sure also to set the same No.
to "#1156".
---Setting range---
000 to 2FF(hexadecimal)
#1156 DOOR_s Signal input device 2 for door interlock II
Set a fixed device No. (X device No.) to input the door lock II signal.
Set the same value as #1155.
---Setting range---
000 to 2FF(hexadecimal)
#1157 F0atrn
Not used. Set to "0".
#1158 F0atno
Not used. Set to "0".
#1164 ATS Automatic tuning function
Select whether to enable or disable the automatic tuning function.
0: Disable
1: Enable
(Note) Enable this parameter when using MS Configurator.
Although later CNC software versions allow constant connection of MS Configurator
while this parameter is set to "0", the available functions are limited.
#1166 fixpro Fixed cycle editing
Select a type of program dealt on the edit/program list/data in/out screen, general program
or fixed cycle.
0: General programs can be edited, etc.
1: Fixed cycles can be edited, etc.
#1167 e2rom
Not used. Set to "0".
#1168 test Simulation test
Select the test mode for the control unit.
In the test mode, test is performed with a hypothetical reference position return complete
even though the real reference position return hasn't been completed. This is limited to test
operation of the control unit itself, and must not be used when the machine is connected.
0: Normal operation mode
1: Test mode