Specifications

Table Of Contents
II Parameters
Base Specifications Parameters
II - 15
#1131 Fldcc
Not used. Set to "0".
#1132 CRT
Not used. Set to "0".
#1133 ofsmem Select how to set up tool wear compensation screen
Select whether to display the # number stored at the previous setup, when selecting the tool
compensation screen.
0: Not display the # number when selecting the screen.
1: Display the stored # number when selecting the screen.
#1134 LCDneg
Not used. Set to "0".
#1135 unt_nm Unit name
Set the unit name.
Set with 4 or less characters consisting of both alphabets and numbers.
If "0" is set, the unit name won't be displayed.
---Setting range---
4 or less characters consisting of both alphabets and numbers
#1138 Pnosel Select screen by parameter number
Select whether to enable the function to select a screen by specifying a parameter number.
0: Disable
1: Enable
#1139 edtype Edit type selection
Select an edit type.
0: Screen edit type (M50 or equivalent operation)
1: Screen edit type
(The screen of EDIT or MDI is changed automatically according to the selected
operation mode.)
2: Word edit type
(The screen of EDIT or MDI is changed automatically according to the selected
operation mode.)
#1140 Mn100 M code number
Set the first number of M code that corresponds to the setup Nos. from 100 to 199.
---Setting range-
0 to 99999999
#1141 Mn200 M code number
Set the first number of M code that corresponds to the setup Nos. from 200 to 299.
---Setting range---
0 to 99999999
#1142 Mn300 M code number
Set the first number of M code that corresponds to the setup Nos. from 300 to 399.
---Setting range---
0 to 99999999
#1143 Mn400 M code number
Set the first number of M code that corresponds to the setup Nos. from 400 to 499.
---Setting range---
0 to 99999999
#1144 mdlkof MDI setup lock
Select whether to enable MDI setting in non-MDI mode.
0: Disable MDI setting
1: Enable MDI setting
#1145 I_abs Manual ABS parameter
Select how to handle the absolute position data during automatic handle interrupt.
0: Absolute position data will be renewed if manual ABS switch is ON. If it is OFF, data
won't be renewed.
1: Follow the "intabs" state when "#1061 intabs" is enabled
#1146 Sclamp Spindle rotation speed clamp function
Select how to handle the spindle rotation speed clamp function with the G92S command.
0: G92S command is handled as a clamp command only in the G96 state (during
constant surface speed control).
G92S will be handled as normal S command in G97 state (constant surface speed
OFF).
1: The S command in the same block as G92 is constantly handled as a clamp
command