Specifications
Table Of Contents
- Front cover
- Trademarks
- Contents
- Remedy and measure after a report of error
- I Alarms
- 1. Operation Errors (M)
- 2. Stop Codes (T)
- 3. Servo/Spindle Alarms (S)
- 4. MCP Alarms (Y)
- 5. Safety Observation Alarms (Y)
- 6. System Alarms (Z)
- 7. Absolute Position Detection System Alarms (Z7*)
- 8. Emergency Stop Alarms (EMG)
- 9. Auxiliary Axis Operation Errors (M)
- 10. CNCCPU-side Safety Sequence Alarm(U)
- 11. Multi CPU Errors (A)
- 12. Network Errors (L)
- 13. Program Errors (P)
- II Parameters
- 1. Machining Parameters
- 2. Base Specifications Parameters
- 3. Axis Specifications Parameters
- 4. Servo Parameters
- 5. Spindle Parameters
- 6. Multi-CPU Parameters
- 7. FL-net Parameters
- 8. DeviceNet Parameters
- 9. Machine Error Compensation Parameters
- 10. PLC Parameters
- 11. Macro List
- 12. Position Switches
- 13. PLC Axis Indexing Parameters
- III PLC Devices
- Revision History
- Back cover

II Parameters
Base Specifications Parameters
II - 14
【#1118】 mirr_A Select how to set up the length of tools on cutter tables (opposed tables)
(for L system only)
Select one of the following two methods:
- Set the current length of tools on each facing turret.
- Set a value, assuming that the tools on each facing turret are in the same direction as that
of those on the base turret.
0: Current length of the tools on each facing turret
1: Value, assuming that the tools on each facing turret are in the same direction as that
of those on the base turret
【#1119】 Tmiron Select the mirror image of each facing turret with T command (for L
system only)
Select whether to enable the mirror image of each facing turret with the T command.
0: Disable
1: Enable
【#1120(PR)】 TofVal Change macro variable
Select whether to change the macro variable (tool offset) numbers for shape compensation
and wear compensation.
0: Not change (Conventional specification)
1: Change the shape and wear compensation variable numbers each for X, Z, and R
【#1121】 edlk_c Edit lock C
Select the edit lock for program Nos. 9000 to 9999 in memory.
0: Editing possible
1: Editing prohibited. The file cannot be opened.
(Note) If “#1122” is set to “1” or “2”, “1” will be set in “#1121” when the power is turned ON.
【#1122(PR)】 pglk_c Program display lock C
Select whether to prohibit the program display and search for program Nos. 9000 to 9999 in
memory.
0: Program display and search is possible
1: Program display is impossible. Search is possible.
2: Program display and search is impossible
The program details will not be displayed‚ but the program No. and sequence No. will
display in the prohibited state.
(Note) If “#1122” is set to “1” or “2”, “1” will be set in “#1121” when the power is turned ON.
【#1123】 origin Origin zero prohibit
Select whether to use the origin zero function.
0: Use
1: Not use
【#1124】 ofsfix Fix tool compensation No.
Select how to handle the compensation No. when the input key is pressed on the tool
compensation screen.
0: Increment the compensation No. by 1 (Same as general parameters)
1: # compensation No. does not change
When setting in sequence, “0” is handier. When changing and setting repeatedly while
adjusting one compensation value, “1” is handier
【#1125】 real_f Actual feedrate display
Select the feedrate display on the monitor screen.
0: Command speed
1: Actual travel feedrate
【#1126】 PB_G90
Not used. Set to "0".
【#1127】 DPRINT DPRINT alignment
Select the alignment for printing out with the DPRINT function.
0: No alignment, output s printed with left justification
1: Align the minimum digit and output
【#1128】 RstVCI Clear variables by resetting
Select how to handle the common variables when resetting.
0: Common variables won't change after resetting.
1: The following common variables will be cleared by resetting:
#100 to #149 when 100 sets of variables are provided.
#100 to #199 when 200 sets or more of variables are provided.
【#1129】 PwrVCl Clear variables by power-ON
Select how to handle the common variables when the power is turned ON.
0: The common variables are in the same state as before turning the power OFF.
1: The following common variables will be cleared when the power is turned ON:
#100 to #149 when 100 sets of variables are provided.
#100 to #199 when 200 sets or more of variables are provided.
【#1130】 set_t Display selected tool number
Select the tool command value display on the POSITION screen.
0: Display T-modal value of program command
1: Display Tool No. sent from PLC