Specifications

Table Of Contents
II Parameters
Base Specifications Parameters
II - 13
#1104 T_Com2 Tool command method 2
Select how to handle the tool command in the program when "#1103 T_Life" is set to "1".
0: Handle the command as group No.
1: Handle the command as tool No.
#1105 T_Sel2 Tool selection method 2
Select the tool selection method when "#1103 T_Life" is set to "1".
0: Select in order of registered No. from the tools used in the same group.
1: Select the tool with the longest remaining life from the tools used or unused in the
same group.
#1106 Tcount Life management (for L system only)
Select the input method when address N is omitted in inputting the data (G10 L3 command)
for tool life management function II.
0: Time specified input
1: Number of times specified input
#1107 Tllfsc Split life management display screen (for L system only)
Set the number of groups to be displayed on the tool life management II (L system) screen.
0: Displayed group count 1, maximum number of registered tools: 16
1: Displayed group count 2, maximum number of registered tools: 8
2: Displayed group count 4, maximum number of registered tools: 4
#1108 TlrectM Life management re-count M code (for L system only)
Set the M code for tool life management II (L system) re-count.
---Setting range---
0 to 99
#1109 subs_M Validate alternate M code
Select the user macro interrupt with the substitute M code.
0: Disable alternate M code
1: Enable alternate M code
#1110 M96_M M96 alternate M code
Set an M code to replace M96 when “#1109 subs_M” is set to “1”.
---Setting range---
3 to 97 (excluding 30)
#1111 M97_M M97 alternate M code
Specify an M code to replace M97 when #1109 subs_M is set to 1.
---Setting range---
3 to 97 (excluding 30)
#1112(PR) S_TRG Validate status trigger method
Select the enable conditions for the user macro interrupt signal (UIT).
0: Enable when interrupt signal (UIT) turns ON
1: Enable when interrupt signal (UIT) is ON
#1113(PR) INT_2 Validate interrupt method type 2
Select the performance after user macro interrupt signal (UIT) input.
0: Execute interrupt program without waiting for block being executed to end
1: Execute interrupt program after completing block being executed
#1114 mcrint Macro argument initialization
Select whether to clear statements other than specified arguments by macro call.
Also select whether to clear local variables by power-ON and resetting.
0: Clear the non-specified arguments by macro call.
1: Hold non-specified arguments by macro call
2: Hold non-specified arguments by macro call, and clear local variables by power-ON
and resetting
#1115 thwait Waiting for thread cutting
Set the queue number during screw thread cutting when chamfering is disabled.
---Setting range---
0 to 99 (Approx. 4 ms)
Standard setting value: 4
#1116 G30SLM Invalidate soft limit (manual operation)
Enable this function when disabling the soft limit check function at the second to fourth
reference position return.
0: Enable soft limit function
1: Disable soft limit function
#1117(PR) H_sens Handle response switch
Not used. Set to "0".