INSTRUCTION MANUAL
ENGLISH FRANÇAIS ESPAÑOL DEUTSCH ITALIANO PORTUGUÊS 中文 (繁体字) 中文 (簡体字)
Thank you for your purchase of this Citizen watch. Before using the watch, read this instruction manual carefully to ensure correct use. After reading the manual, store it in a safe place for future reference. Visit the Citizen web site (http://www.citizenwatch-global.com/) to view visual guides for operation of your watch. Some models may be equipped with external features (calculation scale, tachymeter, etc.). Visual guides for operation of such external features can also be found on the web site.
Safety precautions — IMPORTANT This manual may contain certain safety advisories. Your watch should be used in accordance with these advisories at all times to ensure optimal enjoyment of your watch and to prevent injury to yourself, other persons and/or damage to property. Understand the meaning of the following symbols and read pages from 20 to 33.
Before using this watch After unpacking, the following must be done before using the watch: • Checking whether the second hand moves normally When the second hand moves once every two seconds, charge your watch. (See page 10) This watch has a rechargeable cell which is charged by exposing the dial to light. Expose the dial to direct sunlight regularly to charge the watch. For details of charging, see pages 10 to 13.
Before using this watch Band adjustment We recommend seeking the assistance of an experienced watch technician for sizing of your watch. If adjustment is not done correctly, the bracelet may unexpectedly become detached leading to loss of your watch or injury. Consult your nearest an authorized service center. Protective stickers Be sure to remove any stickers covering the metal parts (back cover, band, clasp) or glass of the watch before use.
Before using this watch Screw down crown and screw down push button Unlock the crown/button prior to operate your watch. Unlock Lock Screw down crown Rotate the crown counterclockwise until it releases from the case. Push the crown in to the case. With gentle pressure towards the case, rotate the crown clockwise to secure it to the case. Be sure to tighten firmly. Screw down push button Rotate the locking screw counterclockwise, and loosen until it stops.
Table of contents Component identification .................................................................8 Charging your watch.......................................................................10 Adjusting the time .........................................................................14 Adjusting the date ..........................................................................16 Troubleshooting .............................................................................
Table of contents Precautionary items and usage limitations......................................27 Specifications .................................................................................
Component identification Model with date/24-hour indicator Equipped with a date hand at the 12 o’clock position, and a 24-hour hand at the 6 o’clock position. ⑥ ① ③ ② ④ Model with date/day indicator Equipped with a date hand at the 3 o’clock position, and a day hand at the 9 o’clock position.
Component identification Model with date/day/24-hour indicator Equipped with a date hand at the 3 o’clock position, a 24-hour hand at the 6 o’clock position, and a day hand at the 9 o’clock position.
Charging your watch This watch has a rechargeable cell which is charged by exposing the dial to light, such as direct sunlight or fluorescent lamps. After taking off the watch, put it in a location where the dial is exposed to bright light, such as by a window. For optimal performance, be sure to: • Expose the watch to direct sunlight for five or six hours at least once a month. • Avoid leaving the watch in dark places for long periods of time.
Charging your watch When the watch reaches a low charge state (insufficient charge warning function) When the power reserve becomes low, the second hand moves once every two seconds. This is the insufficient charge warning function. Be sure to fully charge your watch. • When the watch is sufficiently charged, the second hand will move normally. • If you do not charge the watch for four days or longer after the insufficient charge warning movement has begun, the watch will be depleted of all power and stop.
Charging your watch Charging time by environment Below are the approximate times required for charging when exposing the watch dial to light continuously. Please use this table as a reference only. Charging time (approx.) 12 Environment Illuminance (lx) To work for one day To start working normally when the cell is discharged To become fully charged when the cell is discharged Outdoors (sunny) 100,000 19 minutes 7.
Charging your watch • To charge your watch, it is recommended to expose the dial to direct sunlight. A fluorescent lamp or interior lighting does not have sufficient illumination to charge the rechargeable cell efficiently. Run time From fully charged without extra charging: 6 months (at normal use) About Quick Start function The watch works immediately when the charging starts, even though all the hands are stopped for lack of the power.
Adjusting the time 1 Pull the crown out to position when the second hand points to 0 second. All the hands stop. 2 Rotate the crown to the right (clockwise) to set the day (only for models with a day indicator). 14 Model with date/ Model with date/ day indicator day/24-hour indicator • The day hand moves when the hour hand is indicating between 0 a.m. and 5 a.m. • As the day hand moves in conjunction with the hour/minute hand, adjust the day first and then adjust the time.
Adjusting the time 3 Rotate the crown to adjust the time. • Pay attention the date hand to ensure AM or PM time is set properly. • For more accurate adjustment, first set the minute hand forward by five minutes and then return it to the correct time. 4 Push the crown in to position in accordance with a reliable time source to finish the procedure. • The date indicator begins to change at about 22:30 and has finished changing by about 0:00.
Adjusting the date Adjust the date indication on the first days of March, May, July, October and December. • When the time on the watch is between 21:00 and 0:00, do not execute the adjustment. Otherwise the date indication may change improperly. 1 Pull the crown out to position .
Adjusting the date Model with date/24-hour indicator 2 Rotate the crown counterclockwise to adjust Model with date/day indicator Model with date/day/24-hour indicator the date.
Adjusting the date 3 Push the crown in to position to finish the procedure.
Troubleshooting If you have a problem with your watch, check the table below. Symptoms Remedies Page Movement of a hand seems strange The second hand moves once every two seconds. Fully charge the watch. The second hand does not move. Push the crown in to position Fully charge the watch. 10 to 13 . 15 10 to 13 The date indicator or day indicator is incorrect Adjust the date. The date indicator is incorrect. The day indicator is incorrect. Check that AM or PM time is set properly.
Eco-Drive watch handling precautions • For optimal performance, your watch should remain fully charged. • Long sleeves may inhibit light transmission to your watch. This may result in your watch loosing charge. In these cases supplemental charging may be necessary. • When you take off the watch, place it in a bright location to ensure optimal performance.
Eco-Drive watch handling precautions CAUTION Recharging Precautions • Do not charge the watch at a high temperature (about 60°C/140°F or higher) as doing so may cause the movement to malfunction. Examples: • Charging the watch too close to a light source which generates a large amount of heat such as an incandescent lamp or halogen lamp. * When charging under an incandescent lamp, be sure to leave 50 cm (20 inches) or more between the lamp and the watch to avoid exposing the watch to excessive heat.
Eco-Drive watch handling precautions • This watch utilizes a special rechargeable cell that does not require periodical replacement. However power consumption may increase after using the watch for a number of years due to wear of internal components and deterioration of oils. This may cause stored power to be depleted at a faster rate. For optimal performance, we recommend having your watch inspected every 2-3 years for proper operation and condition check.
Eco-Drive watch handling precautions WARNING Use Only the Specified Battery • Never use a battery other than the rechargeable cell specified for use in this watch. Although the watch structure is designed so that it will not operate when another type of battery is installed, if a conventional watch battery or other type of battery is installed in the watch and the watch is recharged, there is the risk of overcharging which may cause the battery to rupture.
Water resistance WARNING Water Resistance • Refer to the watch dial and/or the case back for the indication of the water resistance of your watch. The following chart provides examples of use for reference to ensure that your watch is used properly. (The unit “1 bar” is roughly equal to 1 atmosphere.) • WATER RESIST(ANT) ××bar may also be indicated as W.R. ×× bar.
Water resistance Water-related use Minor exposure to water (washing face, rain, etc.
Water resistance • Non-water resistant models are not designed to come into contact with any moisture. Take care not to expose a watch with this rating to any type of moisture. • Water resistance for daily use (to 3 atmospheres) means the watch is water resistant for occasional accidental splashing. • Upgraded water resistance for daily use (to 5 atmospheres) means that the watch may be worn while swimming, but is not to worn while skin diving.
Precautionary items and usage limitations CAUTION To Avoid Injury • Be particularly careful when wearing your watch while holding a small child, to avoid injury. • Be particularly careful when engaged in strenuous exercise or work, to avoid injury to yourself and others. • Do not wear your watch while in a sauna or other location where your watch may become excessively hot, since there is the risk of burns.
Precautionary items and usage limitations CAUTION Precautions • Always use the watch with the crown pushed in (normal position). If the crown is of the screw lock-type, make sure it is securely locked. • Do not operate the crown or any push buttons when the watch is wet. Water may enter the watch causing damage to vital components. • If water enters the watch or the watch fogs up and does not clear up even after a long time, consult your dealer or an authorized service center for inspection and/or repair.
Precautionary items and usage limitations CAUTION When Wearing Your Watch • Leather bands and rubber (urethane) bands will deteriorate over time due to perspiration dirt. Because of the natural materials, leather band will be worn, deformed, and discolored over time. It is recommended to replace the band periodically. • The durability of a leather band may be affected when wet (fading, peeling of adhesive), owing to the properties of the material. Moreover, wet leather may cause a rash.
Precautionary items and usage limitations CAUTION When Wearing Your Watch (continued) • Please request adjustment or repair of the band in the following cases: • You notice an abnormality with the band due to corrosion. • The pin of the band is protruding. • We recommend seeking the assistance of an experienced watch technician for sizing of your watch. If adjustment is not done correctly, the bracelet may unexpectedly become detached leading to loss of your watch or injury.
Precautionary items and usage limitations • Avoid dropping the watch or subjecting it to other strong impact. It may cause malfunctions and/or performance deterioration as well as damage to the case and bracelet. • The integrated circuits (IC) used in quartz watches are sensitive to static electricity. Please note the watch may operate erratically or not at all if exposed to intense static electricity.
Precautionary items and usage limitations CAUTION Always Keep Your Watch Clean • Rotate the crown while it is pressed in fully and press the buttons periodically so they do not become stuck due to accumulations of foreign matter. • The case and band of the watch come into direct contact with the skin. Corrosion of the metal or accumulated foreign matter may result in black residue coming from the bracelet when exposed to moisture or perspiration. Be sure to keep your watch clean at all times.
Precautionary items and usage limitations Caring for Your Watch • Wipe any dirt or moisture such as perspiration from the case and crystal with a soft cloth. • For metallic, plastic or synthetic rubber (polyurethane) band, clean it with soap and a soft toothbrush. Be sure to thoroughly rinse the band after cleaning to remove any soap residue. • For a leather band, wipe off dirt using a dry cloth.
Specifications 34 Model 8723/8725/8729 Timekeeping accuracy (without reception) Within ±15 seconds per month when worn at normal operation temperatures (between +5˚C/41°F and +35˚C/95°F) Operating temperature range –10˚C/14°F to +60˚C/140°F Display functions • Time: Hours, minutes, seconds, 24-hour (24-hour indicator: 8723/8729 only) • Calendar: Date, day (Day indicator: 8725/8729 only) Maximum run time from full charge • Fully charged to fully discharged: Approximately 6 months • Power reserve u
Specifications Additional functions • • • • Solar power function Calendar function Overcharging prevention function Insufficient charge warning function (two-second interval movement) • Quick Start function Specifications and contents of this booklet are subject to change without prior notice.
Model No.BU2*・BU3*・BU4* FD2*・FD3*・FD4* Cal.