User`s manual

BD2-2860 User’s Manual
CITIZEN
18
6.4 Timing chart
(1) Data Input and Printing Timing
T1, T2, T3 : 0.5
µ
s(MIN)
T4 : 270 ns (MAX)
T5 : 2.3
µ
s(TYP)
T6 : 500 ms (MIN) *On supplying power
6.5 Data receiving control
When BUSY signal is "LOW", data from the host can be received. When it being "HIGH", data
cannot be received.
6.6 Buffering
This control board incorporates 2K byte buffer.
Therefore, big data can be buffered in input buffer, and the host side can be released immediately.
Supply